Fieldbus PCI-Card
Network setup
Fig. 48 Error:12
To edit a connection in the list, just click on that row. To add a connection press [Add]. To delete a
connection select row and press [Delete]. See Fig. 47 Anybus Master EtherNet/IP 2.
Example below shows connection 5 bytes from an AnyBus Ethernet/IP adapter. Please note the
instance numbering:
Fig. 49 Scanlist configuration
Note
The sum of all Originator->Target is not allowed to be greater than 505 bytes and the sum of
all Target ->Originator is not allowed to be greater than 509 bytes. See Fig. 49 Scanlist
configuration. Be sure not to set greater values or addresses outside these limits.