Connectors; Rectifying Of Interruption - YASKAWA NX100 Instruction Manual

Fieldbus pci-card
Hide thumbs Also See for NX100:
Table of Contents

Advertisement

Fieldbus PCI-Card
Card
No:
4
5
6

9.2.2 Connectors

Fig. 27 Connector PCI AS-interface Master
No:
1
2
3

9.2.3 Rectifying of interruption

Since there are possibilities of AS-interface being affected by interruption, a ferrite clip should be
attached to its bus cable according to Fig. 28 Ferrite clip on cable.
Fig. 28 Ferrite clip on cable
Page 40
Indication
Auto prog, slave 0 exist
Network status
Module status
1
Signal
AS-Interface +
-
AS-Interface -
Meaning
State
Off
No error, no slave 0,
autoprogrammming not possible
8Hz Green
Auto programming possible
1Hz Green
Slave address 0 exist
Red
Periphery error
8Hz Red
Perophery error, auto-programming
possible
1Hz Red
Periphery error, slave address 0 exist
Off
No power or not initialized
Green, flashing
online according to configuration
Green
Online, but no connections
established
Red
Offline
Off
No power or not initialized
Green, flashing
Protected mode
Green
Configuration mode
Red
Power fail bus
2