Components List - Nikon Eclipse Ni-U Instruction Manual

Upright microscope assembly/maintenance
Table of Contents

Advertisement

2

Components List

The ECLIPSE Ni-U components are shown in the table below.
Depending on when you purchased the ECLIPSE Ni-U, there may be devices not yet available for use and devices not
listed that are already available for use. Contact your nearest Nikon representative for details.
Device
Microscope main
ECLIPSE Ni-U (12V 100W 100-240V power supply
body
for illumination integrated)
Precentered lamphouse (12V 100W)
Illuminator for
dia-illumination
Halogen lamp (100W)
Standard arm
Arm
Contact arm
Binocular tube
Trinocular eyepiece tube F
Tube
Trinocular eyepiece tube T
Ergonomic tube
Quadrocular tilting tube
DSC port for ergonomic binocular tube
DSC port
DSC zooming port for quadrocular tube
CFI eyepiece
Eyepiece
Centering telescope
Universal quintuple nosepiece
BD quintuple nosepiece
Sextuple nosepiece
Sextuple nosepiece with analyzer slot
Nosepiece
Sextuple DIC nosepiece
Intelligent DIC sextuple nosepiece
Intelligent Septuple nosepiece
Motorized DIC sextuple nosepiece
Motorized septuple nosepiece
Objective
CFI objective
Substage
Substage
Substage for rotatable ceramic coated stage
Right handle stage with 2S holder
Left handle stage with 2S holder
Right handle ceramic coated stage with 1S holder
Left handle ceramic coated stage with 1S holder
Stage
NI-U right handle rotatable ceramic coated stage
with holder
NI-U left handle rotatable ceramic coated stage with
holder
Condenser holder
Condenser holder
Dark field condenser (Oil) and (Dry)
C-C aplanatic condenser
C-C achromat condenser No.9
C-C abbe condenser No.9
X LWD condenser
Condenser
C-C slide achro condenser 2-100x
C-C achromat swing-out condenser 1-100x
C-C phase turret condenser
DIC condenser (Oil)
Universal condenser (Dry)
Cube turret
Epi-fluorescence
Intelligent epi-fluorescence cube turret
cube turret
Motorized epi-fluorescence cube turret
Epi-fluorescence
Epi-fluorescence attachment
attachment
Mercury lamp
HG precentered fiber illuminator
illuminator
Motorized HG precentered fiber illuminator
Analyzer slider for DIC
Analyzer tube for simple polarization
Analyzer tube for first-order red compensation
Analyzer unit/
Slider
Analyzer slider for simple polarization
Analyzer slider for first-order red compensation
DIC slider
Lambda plate
DIC rotatable polarizer unit
Polarizer unit
Polarizer unit for simple polarization
Polarizer unit for first-order red compensation
Motorized shutter
Shutter
Motorized shutter adapter for upright epi-fl
Motorized shutter adapter for dia-illumination
Control box B
Simple remote control pad
Controller
DS-L3/DS-U3 camera control unit
Eyelevel riser
Eyelevel riser
Variable intermediate
Variable intermediate magnification unit
magnification unit
DSC support column
DSC retention
support
DSC adapter A and B
Tube adapter for
Tube adapter for quadrocular tube
quadrocular tube
TV adapter
TV adapter
Chapter 1
Device Name
Model
ECLIPSE Ni-U
NI-LH
PHILIPS 7724
OSRAM HLX 64623
NI-SAM
NIU-CAM
C-TB
C-TF
C-TT
C-TE2
NI-TT
C-TEP2
NI-RPZ
CFI
CFI UW
C-CT
L-NU5
L-NBD5
C-N
C-NA
D-ND6
NI-ND6-I
NI-N7-I
NI-ND6-E
NI-N7-E
CFI
LU Plan Fluor Epi
LU Plan Fluor BD
NI-SS
NI-SSR
C-SR2S
C-SL2S
C-CSR1S
C-CSL1S
NIU-CSRR2
NIU-CSLR2
NI-CH
D-CUO
NI-CUD
NI-FLT6
NI-FLT6-I
NI-FLT6-E
NI-FLEI
C-HGFI
C-HGFIE
D-DA
C-ISA
C-IA
D-SA
C-AS
D-C
D-LP
D-DP
C-SP
C-TP
NI-SH-E
NI-SHAEP-U
NI-SHADI
NI-CTLB
NI-SRCP
DS-L3
DS-U3
C-ER
Y-IM
NI-RPS
NI-RPSAA
NI-RPSAB
C-TAQ
Y-TV
Y-TV55
Assembly
Combine with a manual model such as manual nosepiece
Combine with a motorized models such as intelligent/motorized nosepiece
C-TBM mildew-proof type also available
C-TFM mildew-proof type also available
Connected to Nikon DS camera head or other C mount camera. Nikon DS camera
head is controlled from DS-L3/DS-U3.
LU Plan Fluor Epi/BD can be attached to the L-NU5 or L-NBD5 nosepiece.
LU nosepiece adapter is required to attach a non-BD objective to L-NBD5.
Rotatable ceramic coated stage can not be attached
Cannot be used when rotatable ceramic coated stage is attached.
Used with OIL DIC module
Supports DRY DIC module, PH module, dark field module, NI-CALN1 2-4x auxiliary
lens, D-C 2-4x auxiliary lens
A filter cube and NI-FA FL/DIC analyzer attachable.
D-FB excitation balancer attachable.
Can be attached to C-NA, D-ND6, NI-ND6-I, NI-N7-I, NI-ND6-E, or NI-N7-E
nosepiece.
Combined with C-SP polarizer unit.
Combined with C-TP polarizer unit.
Can be attached to D-ND6, NI-ND6-I, or NI-ND6-E nosepiece.
Can be attached to D-ND6, NI-ND6-I, or NI-ND6-E nosepiece.
For connection, NI-SHCL motorized shutter cable is required and is connected to the
control box B.
DS-L3 is connected to the control box B via USB cable
DS-L3/DS-U3 is connected to the Ni-U main body or the control box B via C-CTC
camera trigger cable L3/U3
DS camera I/F cable is used to connect to the camera
Can be attached to the quadrocular tilting tube. Attach a C mount camera, ENG mount
camera or a photomicrography device via various adapters.
Y-TV can be attached to C-TF or C-TT trinocular tube. Connect a C mount camera,
ENG mount camera, or photomicroscopy device with an adapter.
Y-TV55 can be attached to C-TF or C-TT trinocular tube. Connect a C mount camera
with C mount adapter 0.55x.
3
Remarks