Nikon Eclipse Ni-U Instruction Manual page 49

Upright microscope assembly/maintenance
Table of Contents

Advertisement

Tube
Arm
Nosepiece
Substage
Stage
Condenser holder
Condenser
Ni-U microscope input ratings
Power cord
Chapter 4
Binocular tube (binocular section 100%)
Trinocular tube F
(Binocular : adapter = 100:0, 0:100)
Trinocular tube T
(Binocular : adapter = 100:0, 20:80, 0:100)
Ergonomic tube
(Binocular section 100%)
(with DSC port mounted, binocular : DSC port = 50:50)
Quadrocular tilting tube
(Binocular : adapter = 100:0, 0:100)
(with DSC port mounted, binocular : adapter : DSC port = 0:0:100)
Standard arm
Contact arm: Required for motorized operation
Universal quintuple, BD quintuple, sextuple, sextuple with analyzer slot, DIC sextuple, intelligent DIC
sextuple, septuple intelligent, motorized DIC sextuple, and motorized septuple
Two types: for standard stage and rotatable ceramic coated stage, one for rotatable ceramic coated
stage is equipped with rotatable stage centering screws
Attached to the elevating section of the main body
• Right/left handle stage (with specimen holder)
• Right/left handle ceramic coated stage (with specimen holder) (Right handle ceramic coated stage
without specimen holder as well)
• Right/left handle rotatable ceramic coated stage (with specimen holder)
Travel range: X: ±78 mm, Y: ±54 mm
Rotation angle: The stage can be rotated clockwise by 195° and counterclockwise by 7° from the
reference position (rotation angle 0°).
Equipped with condenser focus knob, condenser centering screws.
Attached to a substage
Universal condenser: Attach optical modules for differential interference contrast, phase contrast, or
dark-field microscopy to a turret.
C-C phase turret condenser: Optical module for phase contrast and dark-field and shutter embedded
DIC condenser (oil): Differential interference contrast optical module OIL (slider) attached
Other condensers: Abbe condenser, achromat condenser, dark field condenser (dry and oil),
aplanatic condenser, X LWD condenser, 2-100X slide achro condenser, 1-100X achromat swing-out
condenser
100-240VAC, 50/60Hz, 1.7A
• When used in 100-120 V regions outside Japan
UL listed detachable power cord set, 3 conductor grounding
(3 conductor grounding Type SVT, No.18 AWG, 3 m long maximum, rated at 125 VAC minimum)
• When used in 220-240 V regions
Detachable power cord set approved according to EU/EN standard, 3 conductor grounding
(3 conductor grounding Type H05VV-F, 3 m long maximum, rated at 250 VAC minimum)
• When used inside Japan
PSE approved detachable power cord set, 3 conductor grounding
(3 conductor grounding Type VCTF 3 x 0.75 mm
Specifications
2
, 3 m long maximum, rated at 125 VAC minimum)
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents