Installation and Initialization
Hardware Installation
5. Carefully slide the unit to the right until the tabs snap securely onto the narrow holes of the unit. If the unit is mounted
correctly, no portion of the mounting plate should protrude from any of the sides of the unit.
Figure 2-7 Mounting the AP to a Wall
Ceiling Mounting
Follow these steps to mount the unit to a ceiling:
1. If the unit's power supply is plugged in, unplug it.
2. Snap the rectangular tabs on the back of the mounting plate onto a ceiling T-bar. You may need to slightly rotate the
plate until it securely snaps onto the T-bar.
3. Fasten the mounting plate to the ceiling tile with two screws through the circular holes of the plate.
4. Position so that the embossed letter "L" on the mounting plate is facing up (see previous figure). Holding the unit so
that the connectors on the rear are facing to left, align the two holes on the bottom of the unit with the two tabs on the
mounting plate. Press the unit up so it is flush with the plate.
5. Carefully slide the unit to the right until the tabs snap securely onto the narrow holes of the unit. If the unit is mounted
correctly, no portion of the mounting plate should protrude from any of the sides of the unit.

Power On the Unit

The AP can be powered by a power supply (just plug the power cord of the power supply into an AC power outlet), or by
Power-over-Ethernet (connect a PoE DC injector to the Ethernet cable).
When the unit is powered on, it performs startup diagnostics. When startup is completed, the LEDs show the operational
state of the unit.
AP-700 User Guide
23