4.1.7 Paper jam in finisher
EA1 Finisher paper transport delay jam
Is there paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and inlet paper sensor broken?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet paper sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet paper sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet paper sensor.
YES
Replace the finisher controller PWA.
EA2 Finisher paper transport stop jam
Is there paper remaining on the transport path in the finisher or main unit?
YES
Remove the paper.
NO
Is the connector J10 on the finisher controller PWA disconnected?
Is the harness connecting the finisher controller PWA and inlet paper sensor broken?
YES
Connect the connector securely. Replace the harness.
NO
Is the inlet paper sensor working properly? (Check the movement of the actuator.)
NO
1. Connect the connector of the inlet paper sensor securely.
2. Attach the actuator securely if its shaft is out of place.
3. Replace the inlet paper sensor.
YES
Replace the finisher controller PWA.
1600/2000/2500 TROUBLESHOOTING
4 - 26
December 2000 © TOSHIBA TEC