Setting Of Acceleration/Deceleration Time And Acceleration/Deceleration Pattern; Setting Of The Acceleration And Deceleration Time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 110, Pr. 111) - Mitsubishi Electric FR-A720-0.4K Instruction Manual

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

Setting of acceleration/deceleration time
and acceleration/deceleration pattern
4.12 Setting of acceleration/deceleration time and
acceleration/deceleration pattern
Purpose
Motor acceleration/deceleration time
setting
Starting frequency
Set acceleration/deceleration pattern
suitable for application
Automatically set appropriate
acceleration/deceleration time
4.12.1 Setting of the acceleration and deceleration time (Pr. 7, Pr. 8, Pr. 20, Pr. 21,
Pr. 44, Pr. 45, Pr. 110, Pr. 111)
Used to set motor acceleration/deceleration time.
Pr.6
page 161
Set a larger value for a slower speed increase/decrease or a smaller value for a faster speed increase/decrease.
Pr. 9
For the acceleration time at automatic restart after instantaneous power failure, refer to Pr. 611 Acceleration time at
page 176
a restart (page 253).
Pr.19
page 155
Parameter
Pr.22
Number
page 148
Pr.43
7
Acceleration time
page 235
Pr.46
page 142
8
Deceleration time
Pr.109
page 160
Acceleration/
Pr.112
20
deceleration
page 142
reference frequency
Acceleration/
21
deceleration time
increments
Second
44
acceleration/
deceleration time
Second
45
deceleration time
Third acceleration/
110
deceleration time
Third deceleration
111
time
*1
Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and the setting
increments is "0.1s".
Pr.20
(60Hz)
Acceleration
Pr.7
time
Pr.44
Pr.110
Example) When Pr. 20 = 60Hz (initial value), Pr. 13 = 0.5Hz, and acceleration
can be made up to the maximum operating frequency of 50Hz in
10s
168
Acceleration/deceleration time
Starting frequency and start-
time hold
Acceleration/deceleration
pattern and backlash measures
Automatic acceleration/
deceleration
Name
Initial Value
7.5K or less
11K or more
7.5K or less
11K or more
60Hz
5s
9999
9999
9999
(1) Acceleration time setting (Pr. 7, Pr. 20)
⋅ Use Pr. 7 Acceleration time to set the acceleration time required to reach Pr.
Running
20 Acceleration/deceleration reference frequency from 0Hz.
frequency
⋅ Set the acceleration time according to the following formula.
Time
Acceleration
time setting
Deceleration
Pr.8
time
Pr.45
Pr.111
Parameter that must be Set
Setting Range
5s
0 to 3600/360s
15s
5s
0 to 3600/360s
15s
1 to 400Hz
0
0
1
0 to 3600/360s
0 to 3600/360s
9999
0 to 3600/360s
9999
0 to 3600/360s
9999
Pr. 20
=
Maximum operating
frequency - Pr. 13
Pr. 7, Pr. 8, Pr. 20, Pr. 21,
Pr. 44, Pr. 45, Pr. 110, Pr. 111
Pr. 13, Pr. 571
Pr. 29, Pr. 140 to Pr. 143,
Pr. 380 to Pr. 383,
Pr. 516 to Pr. 519
Pr. 61 to Pr. 63, Pr. 292
Description
Set the motor acceleration time.
*1
Set the motor deceleration time.
*1
Set the frequency that will be the basis of
acceleration/deceleration time.
As acceleration/deceleration time, set the
frequency change time from stop to Pr. 20.
Increments: 0.1s
Range: 0 to 3600s
Increments: 0.01s
Range: 0 to 360s
Set the acceleration/deceleration time when
*1
the RT signal is on.
Set the deceleration time when the RT
*1
signal is on.
Acceleration time = deceleration time
Set the acceleration/deceleration time when
*1
the X9 signal is on.
Without the third acceleration/deceleration
function.
Set the deceleration time when the X9
*1
signal is on.
Acceleration time = deceleration time
Acceleration time from stop to
×
maximum operating frequency
60Hz
Pr. 7 =
50Hz - 0.5Hz
Refer to Page
168
170
171
174
Increments and
setting range of
acceleration/
deceleration time
setting can be
changed.
× 10s
12.1s

Advertisement

Table of Contents
loading

Table of Contents