Mitsubishi Electric FR-A720-0.4K Instruction Manual page 443

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

Dedicated motor (SF-V5RU(H)) outline dimension drawings
Frame Number 90L
SF-V5RUF(H)
1K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 160M, 160L, 180M, 180L
SF-V5RUF(H)
11K
,
15K
,
18K
Connector (for encoder)
MS3102A20-29P
LL
KB
LG
Exhaust
Section
AA
Suction
Direction of
Earth (ground) terminal (M8)
cooling fan wind
Mark for earthing (grounding)
With guard wires
Dimensions table
SF-V5RUF
SF-V5RUF1
SF-V5RUF3
SF-V5RUF4
Flange
Frame
Output
Output
Output
Output
Number
No.
(kW)
(kW)
(kW)
(kW)
1.5
FF165
90L
2.2
1.5
FF215
100L
3.7
2.2
1.5
FF215
112M
5.5
3.7
2.2
FF265
132S
7.5
5.5
3.7
1.5
FF265 132M
11
7.5
5.5
2.2
FF300 160M
15
11
7.5
3.7
FF300
160L
18.5
FF350 180M
22
15
11
18.5
15
5.5
FF350
180L
30
7.5
FF400
200L
37, 45
22, 30
18.5, 22
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
LR
KL
Q
LE
LN LZ
QK
A
B
B
A
W
S
For cooling fan (A, B)
Section BB
For motor (U, V, W)
For thermal protector (G1, G2)
A
U
W
G1
G2
B
V
Earthing (grounding)
terminal (M4)
,
22K
LR
Q
LE
LN LZ
KL
QK
A
B
B
A
W
S
Section BB
For cooling fan (A, B, C)
Mass
(kg)
D
IE
KB
KD
KL
LA
26.5
183.6
198.5
27
220
165 130j6 200
37
207
130
213
27
231
215 180j6 250
46
228
141
239
27
242
215 180j6 250
65
266
156
256
27
256
265 230j6 300
70
266
156
294
27
256
265 230j6 300
110
318
207
318
56
330
300 250j6 350
125
318
207
362
56
330
300 250j6 350
160
363
230 378.5
56
352
350 300j6 400
185
225
363
230 416.5
56
352
350 300j6 400
270
406
255
485
90
346
400 350j6 450
290
0
-0.5
Outline dimension drawings
(1500r/min series)
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H)
2K
,
3K
,
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Section
Suction
Direction of
cooling fan wind
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Frame Number 200L
SF-V5RUF(H)
30K
,
37K
Connector (for encoder)
MS3102A20-29P
LL
KB
Exhaust
Suction
Direction of
Earth (ground) terminal (M12)
cooling fan wind
Mark for earthing (grounding)
With guard wires
For motor (U, V, W)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the flange section
For thermal protector (G1, G2)
as well as the earth terminal in the terminal box.
Motor
LB
LC
LE
LG
LL
LN
LZ
LR
3.5
12
402
4
12
50
4
16
432
4
14.5
60
4
16
448
4
14.5
60
4
20
484
4
14.5
80
4
20
522
4
14.5
80
5
20
625
4
18.5
110
5
20
669
4
18.5
110
5
20
690
4
18.5
110
5
20
728
4
18.5
110
5
22
823.5
8
18.5
140
(flange type)
5K
,
7K
LR
Q
LG
LE
KL
QK
AA
A
B
B
W
S
Section BB
,
45K
LR
Q
QK
KL
LG
LE
Section
AA
B
A
B
KD
A
W
S
Section BB
Shaft End
Terminal Screw Size
Q
QK
S
T
U
W
U,V,W A,B,(C) G1,G2
50
40
24j6
7
4
8
M6
60
45
28j6
7
4
8
M6
60
45
28j6
7
4
8
M6
80
63
38k6
8
5
10
M6
80
63
38k6
8
5
10
M6
110
90
42k6
8
5
12
M8
110
90
42k6
8
5
12
M8
110
90
48k6
9
5.5
14
M8
110
90
55m6
10
6
16
M8
140
110 60m6
11
7
18
M10
LN LZ
A
LN LZ
(Unit: mm)
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
M4
7
433

Advertisement

Table of Contents
loading