Mitsubishi Electric FR-A720-0.4K Instruction Manual page 83

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

Func-
Parameter
tion
79
Operation mode selection
80
Motor capacity
81
Number of motor poles
82
Motor excitation current
83
Motor rated voltage
84
Rated motor frequency
89
Speed control gain (magnetic flux vector)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
95
Online auto tuning selection
96
Auto tuning setting/status
100
V/F1(first frequency)
101
V/F1(first frequency voltage)
102
V/F2(second frequency)
103
V/F2(second frequency voltage)
104
V/F3(third frequency)
105
V/F3(third frequency voltage)
106
V/F4(fourth frequency)
107
V/F4(fourth frequency voltage)
108
V/F5(fifth frequency)
109
V/F5(fifth frequency voltage)
110
Third acceleration/deceleration time
111
Third deceleration time
112
Third torque boost
113
Third V/F (base frequency)
114
Third stall prevention operation current 0 to 220%
Thrid stall prevention operation
115
frequency
116
Third output frequency detection
117
PU communication station number
118
PU communication speed
119
PU communication stop bit length
120
PU communication parity check
121
Number of PU communication retries
122
PU communication check time interval
123
PU communication waiting time setting 0 to 150ms, 9999
PU communication CR/LF presence/
124
absence selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
Name
Setting Range
0, 1, 2, 3, 4, 6, 7
0.4 to 55kW, 9999/
0 to 3600kW, 9999
2, 4, 6, 8, 10, 12, 14, 16,
18, 20, 9999
0 to 500A, 9999/
0 to 3600A, 9999
0 to 1000V
10 to 120Hz
0 to 200%, 9999
0 to 50
0 to 400mΩ, 9999
0 to 50
0 to 400mΩ, 9999
0 to 50
0 to 3600mΩ (0 to 400mH), 9999
0 to 50
0 to 3600mΩ (0 to 400mH), 9999
0 to 500
0 to 100Ω (0 to 100%), 9999
0 to 2
0, 1, 101
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 400Hz, 9999
0 to 1,000V
0 to 3600/360s, 9999
0 to 3600/360s, 9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 400Hz
0 to 400Hz
0 to 31
48, 96, 192, 384
0, 1, 10, 11
0, 1, 2
0 to10, 9999
0, 0.1 to 999.8s, 9999
0, 1, 2
0 to 400Hz
0 to 400Hz
Minimum
Setting
Increments
1
0.01/0.1kW
*2
*2
1
0.01/0.1A
*2
*2
0.1V
0.01Hz
0.1%
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω/
, 9999/
0.01mΩ
*2
*2
0.001Ω (0.1mH)/
(0 to 1000mH), 9999/
0.01mΩ(0.01mH)
*2
*2
0.001Ω (0.1mH)/
(0 to 1000mH), 9999/
0.01mΩ(0.01mH)
*2
*2
0.01Ω (0.1%)/
(0 to 100%), 9999/
0.01Ω (0.01%)
*2
*2
1
1
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.01Hz
0.1V
0.1/0.01s
0.1/0.01s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
1
1
1
1
1
0.1s
1
1
0.01Hz
0.01Hz
Parameter List
Refer
Customer
Initial Value
to
Setting
Page
0
295
144,
9999
181
144,
9999
181
9999
181
200/400V
181
*5
60
Hz
181
9999
144
9999
181
9999
181
9999
181
9999
181
9999
181
0
191
0
181
9999
160
0V
160
9999
160
0V
160
9999
160
0V
160
9999
160
0V
160
9999
160
0V
160
9999
168
9999
168
9999
142
9999
155
150%
148
0
148
60Hz
235
0
314
192
314
1
314
2
314
1
314
9999
314
9999
314
1
314
Hz
280
60
60
Hz
280
73
4

Advertisement

Table of Contents
loading