Mitsubishi Electric FR-A720-0.4K Instruction Manual page 199

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

• To enter the Pr. 92 and Pr. 93 motor constants in [mH]
<Operating procedure>
1) Set Pr. 71 according to the motor used.
Motor
Mitsubishi standard
motor
Mitsubishi high
efficiency motor
Mitsubishi constant-
torque motor
Vector control
dedicated motor
*1 For other settings of Pr. 71, refer to the page 179.
2) In the parameter setting mode, read the following parameters and set desired values.
Calculate the Pr. 94 value from the following formula.
Pr. 94 setting = (1 -
R1
I1
V
M
L1= I1+ M: Primary inductance
L2= I2+ M: Secondary inductance
Motor equivalent circuit diagram
Parameter
Number
Motor excitation current
82
(no load current)
90
Motor constant (R1)
91
Motor constant (R2)
92
Motor constant (L1)
93
Motor constant (L2)
94
Motor constant (X)
859
Torque current
3)Refer to the following table and set Pr. 83 and Pr. 84 .
Parameter
Number
83
Motor rated voltage
84
Rated motor frequency
* The initial value differs according to the voltage level. (200V/400V)
REMARKS
· When "9999" is set in Pr. 90 to Pr. 94
SF-JR
SF-JR 4P 1.5kW or less
SF-HR
SF-JRCA 200V 4P
SF-TH (constant torque)
SF-HRCA 200V 4P
SF-V5RU
2
M
×
)
100 (%)
×
L1
L2
I2
R1: Primary resistance
R2: Secondary resistance
I1: Primary leakage inductance
R2/S
I2: Secondary leakage inductance
M: Excitation inductance
S: Slip
Name
55K or less
75K or more
55K or less
75K or more
55K or less
75K or more
55K or less
75K or more
55K or less
75K or more
55K or less
75K or more
55K or less
75K or more
Name
Setting Range
10 to 120Hz
,
Mitsubishi motor (SF-JR, SF-HR,SF-JRCA, SF-HRCA) constants are used.
Selection and protection of a motor
Pr.71 Setting
0
20
40
1
50
30
Setting Range
0 to 500A
0 to 3600A
0 to 50Ω, 9999
0 to 400mΩ, 9999
0 to 50Ω, 9999
0 to 400mΩ, 9999
0 to 1000mH, 9999
0 to 400mH, 9999
0 to 1000mH, 9999
0 to 400mH, 9999
0 to 100%, 9999
0 to 100%, 9999
0 to 500A
0 to 3600A
Setting
Increments
0.1V
0 to 1000V
0.01Hz
Setting
Initial
Increments
Value
0.01A
9999
0.1A
0.001Ω
9999
0.01mΩ
0.001Ω
9999
0.01mΩ
0.1mH
9999
0.01mH
0.1mH
9999
0.01mH
0.1%
9999
0.01%
0.01A
9999
0.1A
Initial
Value
200V/400V*
60Hz
189
4

Advertisement

Table of Contents
loading