Communication operation and setting
Parameter
Parameters Register
41000 to
0 to 999
41999
C2(902)
41902
42092
C3(902)
43902
125(903)
41903
42093
C4(903)
43903
C5(904)
41904
42094
C6(904)
43904
126(905)
41905
42095
C7(905)
43905
C12(917)
41917
42107
C13(917)
43917
C14(918)
41918
42108
C15(918)
43918
C16(919)
41919
42109
C17(919)
43919
C18(920)
41920
42110
C19(920)
43920
C38(932)
41932
42122
C39(932)
43932
C40(933)
41933
42123
C41(933)
43933
338
Parameter Name
Refer to the parameter list (page 71) for
the parameter names.
Terminal 2 frequency setting bias
(frequency)
Terminal 2 frequency setting bias
(analog value)
Terminal 2 frequency setting bias
(terminal analog value)
Terminal 2 frequency setting gain
(frequency)
Terminal 2 frequency setting gain
(analog value)
Terminal 2 frequency setting gain
(terminal analog value)
Terminal 4 frequency setting bias
(frequency)
Terminal 4 frequency setting bias
(analog value)
Terminal 4 frequency setting bias
(terminal analog value)
Terminal 4 frequency setting gain
(frequency)
Terminal 4 frequency setting gain
(analog value)
Terminal 4 frequency setting gain
(terminal analog value)
Terminal 1 bias frequency (speed)
Terminal 1 bias (speed)
Terminal 1 bias (speed)
(terminal analog value)
Terminal 1 gain frequency (speed)
Terminal 1 gain (speed)
Terminal 1 gain (speed)
(terminal analog value)
Terminal 1 bias command (torque/
magnetic flux)
Terminal 1 bias (torque/magnetic flux)
Terminal 1 bias (torque/magnetic flux)
(terminal analog value)
Terminal 1 gain command (torque/
magnetic flux)
Terminal 1 gain (torque/magnetic flux)
Terminal 1 gain (torque/magnetic flux)
(terminal analog value)
Terminal 4 bias command (torque/
magnetic flux)
Terminal 4 bias (torque/magnetic flux)
Terminal 4 bias (torque/magnetic flux)
(terminal analog value)
Terminal 4 gain command (torque/
magnetic flux)
Terminal 4 gain (torque/magnetic flux)
Terminal 4 gain (torque/magnetic flux)
(terminal analog value)
Read/Write
The parameter number + 41000 is the
Read/write
register number.
Read/write
The analog value (%) set to C3 (902) is
Read/write
read.
The analog value (%) of the voltage (current)
Read
applied to the terminal 2 is read.
Read/write
The analog value (%) set to C4 (903) is
Read/write
read.
The analog value (%) of the voltage
Read
(current) applied to the terminal 2 is read.
Read/write
The analog value (%) set to C6 (904) is
Read/write
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
The analog value (%) set to C7 (905) is
Read/write
read.
The analog value (%) of the current (voltage)
Read
applied to the terminal 4 is read.
Read/write
Read/write
Analog value (%) set in C13 (917) is read.
Analog value (%) of the voltage applied to
Read
terminal 1 is read.
Read/write
Read/write
Analog value (%) set in C15 (918) is read.
Analog value (%) of the voltage applied to
Read
terminal 1 is read.
Read/write
Read/write
Analog value (%) set in C17 (919) is read.
Analog value (%) of the voltage applied to
Read
terminal 1 is read.
Read/write
Read/write
Analog value (%) set in C19 (920) is read.
Analog value (%) of the voltage applied to
Read
terminal 1 is read.
Read/write
Read/write
Analog value (%) set in C39 (932) is read.
Analog value (%) of the current (voltage)
Read
applied to terminal 4 is read.
Read/write
Read/write
Analog value (%) set in C41 (933) is read.
Analog value (%) of the current (voltage)
Read
applied to terminal 4 is read.