Section 2: Command Codes
Command Structure
Command Function
Input to Printer
Printer Output
SATO Programming Reference

Start/Stop Label

Start Command:
<ESC>A
Stop Command:
<ESC>Z
Example:
See above
Placement:
<ESC>A must precede data <ESC>Z must follow
data
Default:
None
For all print jobs, the Start command must precede the data, and the Stop
command must follow. The print job will not run properly if these are not in
place.
<ESC>A
<ESC>H0001<ESC>V0100<ESC>WB1SATO
<ESC>H0130<ESC>V0200<ESC>B103150*M-8485S*
<ESC>H0170<ESC>V0360<ESC>L0202<ESC>S*M-8485S*
<ESC>Q1<ESC>Z
There is no output for these commands they are not accompanied by
other label printing commands. However, these commands must precede
and follow each print job sent to the printer.
PN 9001096 Rev. A