Appendic B. Bar Code Specifications
COMMAND STRUCTURE
CHARACTER SET
NOTES
EXAMPLE
Page B-20

Maxicode

<ESC>BVa,b,c,ddddddddd,eee,fff,gggg.....<ESC>
a
=
Position of Maxicode symbol within the set, when used in
a structured append format 1~8.
b
=
Total number of Maxicode symbols in the set, when used
in a structured format 1~8.
c
=
2
3
4
5
6
ddd..ddd
=
9 digit numeric Postal Code
eee
=
3 digit numeric Country Code
fff
=
3 digit numeric Service Class
gg//g
=
Data, terminated by <ESC>
Mode
Postal Cde
9 digits max
2
numeric only
6 digits fixed
3
alphnumeric
4
"000000"
6
fixed data
See AIM I.S.S specification for information on the structure of this
symbology.
<ESC>A<ESC>V0100<ESC>H0100
<ESC>BV1,1,2,123456789,840,001,[)><RS>01<GS>961Z01547089
<GS>UPSN<GS>056872<GS>349<GS>99999999<GS>001/005
<GS>029<GS>N<GS><GS>LENEXA<GS>KS<RS><EOT>
<ESC>Q001<ESC>Z
For Mode 2 Structured Carrier Message for Domestic
U.S. UPS shipments
For Mode 3 Structured Carrier Message for
International UPS shipments
Standard symbol
Not currently supported
Reader programming
Country Code
Service Class
3 digits max
3 digits max
numeric only
numeric only
3 digits numeric
3 digits max
only
numeric only
"000"
"000"
fixed data
fixed data
SATO Programming Reference
Message
Length
84 characters
alphanumeric
84 characters
alphanumeric
91 characters
alphanumeric