Section 7: Bi-Directional Communications
INTERFACE STATUS (SOH + IG)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII IG
causes the printer to return a 1 byte Interface Status Word bounded by an STX-ETX
pair that reports the type of interface connection currently set in the printer.
BYTE
NUMBER
1
SERIAL INTERFACE SETTINGS (SOH + H2)
Upon Receipt of an SOH (hexadecimal 01) followed immediately by an ASCII H2
causes the printer to return a 5 byte Serial IF Status Word bounded by an STX-ETX
pair that reports the current operating parameters of the Serial RS232 Interface.
BYTE
NUMBER
1
2
3
4
STATUS BYTE DEFINITION, BI-COM PROTOCOL
ASCII
0
1
2
3
Page 7-8
VALUE
0
IEEE 1284 Parallel
1
Serial RS232
2
Local Area Network
3
Universal Serial Bus
VALUE
0
9600 BPS
1
19200 BPS
2
38400 BPS
3
57600 BPS
0
No Parity
1
Odd Parity
3
Even Parity
0
1 Stop Bit
1
2 Stop Bits
0
Single Item Buffer with Ready/Busy Flow Control
1
Multi-Item Buffer with Ready/Busy Flow Control
2
X-ON/X-OFF Flow Control
3
Status 4 Bi-Comm
4
Status 3 Bi-Comm
HEX
OFF-LINE
30
No Errors
31
Ribbon Near End
32
Buffer Near Full
33
Ribbon Near End and Buffer Near Full
DESCRIPTION