Esc+2D20 Maxicode - SATO S84EX Programming Reference Manual

Hide thumbs Also See for S84EX:
Table of Contents

Advertisement

76.1 2D code
76.1

ESC+2D20 MaxiCode

MaxiCode
Hexadecimal
ESC
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within item
command
Valid range between item
[Function]
Specify the MaxiCode.
[Format](setting part)
<2D20>,a(,bbb,ccc,d~d)
●Parameter
a [Mode]
=
* Please specify the below parameter when mode 2 or 3 is specified.
Please omit the below parameter when mode 4 or 6 is specified.
b[Service class]
=
c[Country code]
=
d[Postal code]
=
[Format] (data part)
<DN>mmmm,n~n
●Parameter
m[Number of data]
=
n[Print data]
=
Mode
Service class
2
Fixed to 3 digits
3
(Numeric only)
4
6
[Coding Example]
Mode: For carrier (numeric), Service class: 003, country code : 081
Postal code: 123456789
<A>
<V>100<H>200<2D20>,2,003,081,123456789
<DN>0010,0123456789
<Q>2
<Z>
[Notes]
1. The size of the MaxiCode does not vary depending on the number of data.
2. The code will not be printed when a parameter other than above is specified or number of print data does not match.
3. Specify more than 12 for the print data when mode 4 or 6 is specified. The MaxiCode that print data are equal or less
than 11 cannot be read by scanners.
4. The maximum number of print data varies depending on the print data combination when other than alphanumeric code
are used for the print data.
5. The generation module has been changed for the quality improvement. The generated image may be different, however, the
reading result is the same.
2D20
<32>
<44>
<32>
<30>
16
16
16
16
2
:
For carrier (numeric)
3
:
For carrier (alphanumeric)
4
:
Standard code
6
:
For reading device
Valid range:
001~999 (numeric)
Valid range:
001~999 (numeric)
Valid range:
0~999999999 (mode 2)
000000~999999 (mode 3)
* Maximum 9 digits for mode 2 (only numeric)
Fixed to 6 digits for mode 3 (upper case only for alphabet)
Valid range
:
1~138
data
* 00H can not be specified.
Country code
Fixed to 3 digits
(Numeric only)
Omit
ESC+2D20
Parameter
,a(,bbb,ccc,d~d)
The set parameter is not maintained.
The parameter preset will be invalid.
The parameter preset will be invalid.
The maximum number of
Postal code
Numeric
only
Maximum 9 digits
Fixed to 6 digits
123
(alphanumeric)
138
132
print data
Alphanumeric
84
93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S86ex

Table of Contents