Gateway and ATA Placement

You can place the Gateway or ATA on a tabletop, mount it into a standard 19-inch metal rack, or wall mount it. The PSTN Gateway
must be installed within three feet of the building ground point. Install each device using the following instructions.

Rack Mounting

To mount the Gateway or ATA into a standard 19-inch rack:
Locating Indent
Figure 14. Rack-mount Bracket
Figure 15. Bracket Installed
Installation
Synapse Installation Guide
1. Remove the two mounting brackets and six screws from the packing tissue.
2. Position a bracket at the front of the device, as shown in Figure 14.
3. To align the screw holes, place the bracket on the device so that the locating
indent on the bracket matches the indent on the device.
4. Insert each of the three screws into the holes provided and tighten securely as
shown in Figure 15. Repeat the process for the other bracket.
5. Position the chassis into the 19-inch metal
rack, as shown in Figure 16..
6. Insert a top mounting screw (not included)
in one side and turn it several turns to
establish support. Repeat for the other
side.
7. Tighten the screws.
37
Figure 16. Rack Installation