Lexmark X651de Service Manual page 119

Hide thumbs Also See for X651de:
Table of Contents

Advertisement

Error
code or
Error contents
message
920.75
Fuser under
temperature
Fuser type = 2
Fuser page count has
exceeded life.
920.76
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
920.77
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
920.78
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
920.79
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
920.81
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
920.82
Fuser warm-up failure
Fuser type = 2
Fuser page count has
exceeded life.
922.00
Fuser warm-up failure
Fuser type = 1
Description/Action
Fuser does not maintain proper
operating temperature within
steady state control.
The fuser hot roll took too long
to heat up after transitioning to
new enhanced mode within
standby control only.
The fuser hot roll fell to far
below desired temperature
while in standby control.
The fuser hot roll is too cool
while checking for slope
change in standby.
The fuser hot roll is too cool
when heating to desired
temperature after slope change
within standby control only.
The fuser hot roll temperature
does not increase while the
lamp is turned on.
The fuser hot roll temperature
is not maintained properly
while the media in the fuser
nip.
The fuser hot roll failed to
reach target departure.
Possible repair actions
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
Replace the fuser unit
assembly if problem remains.
Go to
"Fuser unit assembly
removal" on page
4-16.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to
"Fuser unit
assembly removal" on
page
4-16.
Diagnostic information
7462
Previous
Next
Go Back
2-85