DCR-PC101/PC101E
RadarW
RadarW
RadarW
3. MR Adjustment
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value 1
Specified value 2
Specified value 3
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: Perform "Flange Back Adjustment" after this adjustment.
Note 3: Check that the data of page: 0, address: 10 is "00".
Note 4: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Switch setting
1) POWER ................................................................... CAMERA
Adjusting method:
Order Page Address Data
1
0
01
2
6
01
3
6
02
5A
5B
4
F
5C
5D
5E
60
5
F
62
64
5F
61
6
F
63
65
Note 5: The adjustment data will be automatically input to page:
F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
0
01
Not required
Adjusting remote commander
F
58, 5A to 65
40 to C0
03 to 78
88 to FD
Procedure
01
BD Press PAUSE button. (Note 5)
Check the data changes to
"01".
Check that the data of each
address satisfied the specified
value 1.
Check that the data of each
address satisfied the specified
value 2.
Check that the data of each
address satisfied the specified
value 3.
Procedure
00
Press PAUSE button.
00
5-22