3-4 Replacing Consumable Parts
4.
Discard any maintenance liquid that has collected in the tray.
Remove the screws shown in the figure and pull out the
tray.
Tray
Screws
Tilt the tray to pour out the maintenance liquid to the
location shown in the figure.
Take up any remaining maintenance liquid with the syringe.
Immediately discard the taken-up maintenance liquid into the drain
bottle, leaving none inside the syringe. Otherwise the rubber parts
Syringe
of the syringe may swell and make the syringe unusable.
Tube
Return the tray to its original location and tighten the
screws.
Screws
72