Check-Control Messages - Faema E92 Manual

Hide thumbs Also See for E92:
Table of Contents

Advertisement

English
11.

Check-control messages

MALFUN.
DESCRIPTION
CODE
Pressure sensor signal out of
51
range
53
Autosteam thermocouple signal
out of range
Boiler overpressure alarm
58
(only for machines with a pressure
sensor)
Boiler: Refill timeout
59
- 15 minutes
Irregular dose coffee cycle
66
Historical
malfunctions
98
wash 1 reset
Default data input
99
POSSIBLE CAUSES
• Sensor failure
• Card failure
• Thermocuple
disconnected
• Wrong configuration
during standard data
insertion
• Level probe failure; boiler
overfilled.
• Resistance always
powered.
• No water
• Refill EV failure
• Wiring interrupted
• Card failure
• No water
• Flowmeter failure
• Water circuit blocked
• Wiring interrupted/
grounded
and
• Breakdown log
initialization.
171
VERIFICATIONS and SOLUTIONS
• Check cabling
• Replace the sensor
• Replace the card
• Enter in the programming mode and insert the correct
standard data..
• Check connections.
• Replace Turbosteam probe.
• Check cabling
• Check water is supplied from the main line.
• Check there are no fitting obstructions or leakage.
• Check flowmeter electrical connections.
• Replace the broken flowmeter.
• Replace the broken board.