1
9.

Technician programming - Configuration menu - Components test

CONFIGURATION
COMPONENTS TEST
Permit parts to be manually operated using the "+" (34) and "-" (35)
keys.
Press the PROG key (32), the following message appears on the
display:
P 1.1bar
±
PRG
Press "+" (34) or "-" (35) to display the various components.
A successive pressure of PROG key (32), visualizes on display the
following panel:
P 1.1bar
±
PRG
Press "+" (34) or "-" (35) to activate the components:
P 1.1bar
±
PRG
4 4 4
4 4 4
4 4 4
4 4 4
4 4 4
Press
(33) to quit manual mode.
u
+
u
8 ON
OFF
u
+
u
Liv.
OK
MP :RES
Liv.
OK
MP :OFF
Liv.
OK
MP :ON
Dip settings
Under standard conditions, the dip-switches are positioned on OFF.
- DIP 1 = OFF - ON Input of standard data
- DIP 2 = OFF
- DIP 3 = OFF - ON Simulation of engineer's key
- DIP 4 = OFF - ON Bookkeeping
- DIP 5 = OFF - ON allows keys sequence to enter programming
- DIP 6 = OFF
- DIP 7 = OFF
- DIP 8 = ON
For more details, please consult the "Setting - CPU Dip-Switch"
paragraph.
P
Boiler pressure, displayed in "bar" or "psi".
Liv
Water level in boiler
Here is the table of symbols used to define the moving parts
that can be accessed:
MP
Pump motor
G1÷G4
Coffee dispensing solenoid valvev
Eac
Hot water solenoid valve
Evc
Boiler load solenoid valve
Ets
Steam solenoid valve (Turbosteam)
M C
Turbosteam compressor motor
Eds
EDS solenoid valve
Em
Milk solenoid valve
169
Legend