Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following table
before calling the servicing department.
DEFECT
The coffee machine does not function
and the indicator light (2) is off.
The coffee machine does not work but
the indicator light (2) is on.
The coffee machine does not heat up.
Leak from edge of filter-holder (21,
25).
Coffee flow time too short.
Water leaks from under the machine.
The coffee is warm and weak (after
normal time of brew and flow).
The reading on the pressure gauge
(8) of the pump pressure is greater
than 9 bars.
CAUSE
No electricity.
Wrong programming of the switch-on
times.
Wrong position of the switch (1a).
The undercup gasket is dirty with
coffee residue.
Coffee grinds too coarse.
Coffee too old.
Drainage tank clogged.
Air
bubble
in
thermosyphonic
circulation system.
The pump's by-pass valve is blocked.
58
REMEDY
Check that the electricity is on.
Check the position of the main switch
(12).
Press the PROGR (32) key for a few
seconds to force switch-on.
Reprogram the clock
Press the switch knob (1a).
Clean with the supplied brush.
Grind the coffee more finely.
Change the coffee
Clean the tank.
Press the coffee distribution button 2/
3 times to try and eliminate the air
bubble.
Call
the
authorized
department.