10.

Technician programming - Configuration menu - Autosteam (Turbosteam)

Once you have selected AUTOSTEAM, use the "+" (34) and "-" (35)
keys to position the cursor on the T STOP STEAM line, and press the
PROG (32) key.
TURBOSTEAM
T stop steam
You may now program the automatic steam function, by setting a
"xxx°C" temperature value for either hot or whipped milk.
Setting options:
"0" setting:
• manual steam stop
Any number between "40°C ÷ 85°C" (104°F ÷ 185°F)
• automatic steam stop
"OFF" setting:
• steam stop disabled
Use the "+" (34) and "-" (35) keys also to modify the message or
number.
444
444
444
444 (33) is pressed, the following message is again
When the key444
displayed:
TURBOSTEAM
T stop steam
The other Autosteam selection parameters that can be modified are:
- regolator - YES/ NO.
- emulsion level - 001 ÷ 004 ( the machine does not have the flow
regolator)
Autosteam can be programmed in two ways:
FIRST WAY: AUTOMATIC STEAM STOP
Set the temperature at the entry "T stop steam xxx°C" using the "+"
and (34) and the "-" (35) keys, with "xxx" set between 40º and 85ºC.
Steam is dispensed when the key (12) is pressed, and the lever (11)
is pressed for the type of milk.
In particular:
- lever down: foamed milk
- lever up: heated milk.
After pressing the key (12), the temperature detected by the probe
appears on the display.
N.B.: When the set temperature is reached, steam supply stops
automatically and the display continues indicating steam value
for the next 5 minutes.
Steam can be stopped at any time (even if the set temperature has
not been reached) by pressing the automatic steam key again (12).
MODE 2, STEAM MANUAL STOP
Set the temperature value on item "T stop steam xxx°C" at "000" zero.
Steam dispensing and the choice of milk type are performed as in
MODE 1
Press the key (12) to dispense steam.
Immediately the message "T stop steam xxx°C" appears on the
display, indicating the temperature read by the probe.
Note: The user controls when steam dispensing is stopped. When
the desired temperature is reached, the user will push on key (12).
For the next 5" after steam dispensing has stopped, the display
shows the milk temperature that has been reached.
Time out is set at 180" for both the programming modes.
u
+
081°C
u
u
+
081°C
u
12
Frothed milk
If, when the machine is powered up, the probe does not detect any
temperature value (thermo-couple not operating), the STOP STEAM
function is disabled and "----" is shown in the setting square instead
of "xx°C". The latest set temperature value is, however, saved until
thermo-couple operation is restored.
The machine works as if the STOP STEAM function does not exist.
Frothed milk and hot milk are available, but the temperature read by the
probe will not appear on the display.
(Where is present)
The ideal setting for milk frothing is set in the factory. If additional
adjustments must be made, turn the flow adjustment valve (A) under
the basin on the right hand side of the machine:
-
counterclockwise: more air > more frothy milk
-
clockwise: less air > less frothy milk
Note: even slight turns of the valve (A) can make a great
difference in how the milk is frothed.
170
12
11
9
Hot milk
A