Appendix 1-2 Replacement Of The Fr-A200 <Excelent> Series; Instructions For Installation - Mitsubishi Electric FR-A700 Instruction Manual

Fr-a700 series to 03460-na/09620-na/00330-n4/00170-n4
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

(5) Main differences and compatibilities with the FR-A500(L) series
Item
V/F control
Control method
Advanced magnetic flux vector control
User group 1 (16), user group 2 (16)
(Pr. 160, Pr. 173 to Pr. 175)
User initial value setting (Pr. 199)
Changed/cleared
functions
Long wiring mode
(Pr. 240 setting 10, 11)
Intelligent mode selection
(Pr. 60)
Program operation
(Pr. 200 to Pr. 231)
PID action set point setting
(Pr. 133)
Number of motor poles
(Pr. 81 , Pr. 144)
Performing parameter clear and all clear (H5A96,
HAA99) with the FR-A7ND clears Pr. 345 and Pr. 346.
Terminal block
Removable terminal block
PU
FR-PU04, DU04
Plug-in options
Computer link, relay output option
FR-A5NR
· FR-A720-00030 to 03460, FR-A740-00015 to 00170, 00380 to 01100, 02160, 03250 are compatible in
mounting dimensions
For the FR-A740-00230, 00310, an optional intercompatibility attachment (FR-AAT) is necessary.
Installation size
· Heatsink protrusion attachment is not compatible.
Also, the panel cut dimension of FR-A720-00030 to 00175, 01150, 02150 or more, FR-A740-00015 to
00090, 00230, 00310, 01440 or more is not compatible.
Appendix 1-2 Replacement of the FR-A200 <EXCELENT> series

Instructions for installation

• When using the installation holes of the FR-A200(E) series, FR-A5AT (intercompatibility attachment) is necessary.
FR-A500(L)
Dedicated plug-in option (incompatible)
FR-A700
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (used with a plug-in option FR-A7AP)
User group (16) only
Setting methods were partially changed
(Pr. 160, Pr. 172 to Pr. 173)
User initial value setting (Pr. 199) was cleared
Substitutable with the copy function of the operation
panel (FR-DU07)
Setting is not necessary
(Pr. 240 settings "10" and "11" were cleared)
Parameter number change
(Pr. 60 Energy saving control selection)
(Pr. 292 Automatic acceleration/deceleration)
Function was cleared
Addition of "9999" to PID action set point (Pr. 133)
setting (a value input from terminal 2 is a set point)
Setting the number of motor poles in Number of motor
poles (Pr. 81) automatically changes the speed setting
switchover (Pr. 144) setting.
Pr. 345 and Pr. 346 are not cleared.
Removable terminal block
Upward compatibility (A500 terminal block mountable)
FR-PU07
FR-DU07
FR-PU04 (Some functions, such as parameter copy,
are unavailable.)
FR-DU04 unavailable
Built into the inverter
(RS-485 terminals, relay output 2 points)
453

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Table of Contents