Mitsubishi Electric FR-A700 Instruction Manual page 247

Fr-a700 series to 03460-na/09620-na/00330-n4/00170-n4
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Setting
Signal
Positive
Negative
Name
Logic
Logic
14
114
FDN
PID lower limit
15
115
FUP
PID upper limit
PID forward/reverse
16
116
RL
rotation output
17
MC1
Electronic bypass MC1
18
MC2
Electronic bypass MC2
19
MC3
Electronic bypass MC3
Brake opening
20
120
BOF
request
25
125
FAN
Fan fault output
Heatsink overheat
26
126
FIN
pre-alarm
27
127
ORA
Orientation in-position
28
128
ORM
Orientation error
30
130
Y30
Forward rotation output
Reverse rotation output Output when the motor is running in reverse
31
131
Y31
Regenerative status
32
132
Y32
output
33
133
RY2
Operation ready 2
34
134
LS
Low speed output
35
135
TU
Torque detection
36
136
Y36
In-position
Start time tuning
39
139
Y39
completion
41
141
FB
Speed detection
Second speed
42
142
FB2
detection
43
143
FB3
Third speed detection
44
144
RUN2 Inverter running 2
Inverter running and
45
145
RUN3
start command is on
During deceleration at
occurrence of power
46
146
Y46
failure (retained until
release)
During PID control
47
147
PID
activated
64
164
Y64
During retry
70
170
SLEEP PID output interruption
Position control
84
184
RDY
preparation ready
85
185
Y85
DC feeding
Function
Output when the feedback value falls below
the lower limit of PID control.
Output when the feedback value rises above
the upper limit of PID control
Output when forward rotation is performed in
PID control.
Used when the commercial power supply-
inverter switchover function is used.
Output to open the brake when the brake
sequence function is selected.
Output at the time of a fan fault.
Output when the heatsink temperature
reaches about 85% of the heatsink overheat
protection providing temperature.
When orientation is valid
Output when the motor is running in forward
direction.
*4
direction.
*4
Output in the regenerative status under
vector control operation.
Output during pre-exitation or operation under
real sensorless vector control.
Output when the output frequency reduces
below the Pr. 865 setting.
Output when the motor torque rises above
the Pr. 864 value.
Output when the number of droop pulses has
fallen below the setting value.
Output on completion of start-time tuning.
Output when the actual motor speed
(estimated actual speed value) reaches the
Pr. 42 (Pr. 50, Pr.116) setting.
⋅ Output during forward rotation or the
reverse rotation signal is on.
⋅ Output at deceleration even during forward
rotation or the reverse rotation signal is off.
(Does not output during pre-excitation LX is
on.)
⋅ Output during the orientation command
signal (X22) is on.
⋅ Switched on when the servo is on (LX-ON)
under position control. (Switched off when
tne servo is off (LX-OFF))
Output when the inverter is running and start
command is on.
Output when the power failure-time
deceleration function is executed.
Output during PID control.
Output during retry processing.
Output when the PID output interruption
function is executed.
Output when the servo is on (LX-ON) and
ready to operate.
Output during power failure or under voltage
of AC power.
Function assignment of external terminal and control
Operation
Pr. 127 to Pr. 134,
Pr. 575 to Pr. 577
Pr. 135 to Pr. 139,
Pr. 159
Pr. 278 to Pr. 285,
Pr. 292
Pr. 244
Pr. 350 to Pr. 366,
Pr. 369, Pr. 393,
*4
Pr. 396 to Pr. 399
*4
Pr. 865
Pr. 864
Pr. 426
Pr. 95, Pr. 574
Pr. 42, Pr. 50,
Pr. 116
Pr. 261 to Pr. 266
Pr. 127 to Pr. 134,
Pr. 575 to Pr. 577
Pr. 65 to Pr. 69
Pr. 127 to Pr. 134,
Pr. 575 to Pr. 577
Pr. 419, Pr. 428 to
Pr. 430
*4
Pr. 30, Pr. 70
Related
Refer to
Parameters
Page
355
363
214
379
406
217
241
241
241
239
243
246
137
197
243
239
239
265
355
268
355
134
204
237
4