Parameter List
Func-
Parameter
tion
C0
FM terminal calibration
(900)
C1
AM terminal calibration
(901)
C2
Terminal 2 frequency setting bias
(902)
frequency
C3
Terminal 2 frequency setting bias
(902)
125
Terminal 2 frequency setting gain
(903)
frequency
C4
Terminal 2 frequency setting gain
(903)
C5
Terminal 4 frequency setting bias
(904)
frequency
C6
Terminal 4 frequency setting bias
(904)
126
Terminal 4 frequency setting gain
(905)
frequency
C7
Terminal 4 frequency setting gain
(905)
C12
Terminal 1 bias frequency (speed)
(917)
C13
Terminal 1 bias (speed)
(917)
C14
Terminal 1 gain frequency (speed)
(918)
C15
Terminal 1 gain (speed)
(918)
C16
Terminal 1 bias command (torque/
(919)
magnetic flux)
C17
Terminal 1 bias (torque/magnetic flux)
(919)
C18
Terminal 1 gain command (torque/
(920)
magnetic flux)
C19
Terminal 1 gain (torque/magnetic flux)
(920)
C38
Terminal 4 bias command (torque/
(932)
magnetic flux)
C39
Terminal 4 bias (torque/magnetic flux)
(932)
C40
Terminal 4 gain command (torque/
(933)
magnetic flux)
C41
Terminal 4 gain (torque/magnetic flux)
(933)
989
Parameter copy alarm release
990
PU buzzer control
991
PU contrast adjustment
Pr. CL
Parameter clear
ALLC
All parameter clear
Er.CL
Alarm history clear
PCPY
Parameter copy
*1
Differ according to capacities.
6%: FR-A720-00030, 00050 (FR-A740-00015, 00025)
4%: FR-A720-00080 to 00175 (FR-A740-00040 to 00090)
3%: FR-A720-00240, 00330(FR-A740-00120, 00170)
2%: FR-A720-00460 to 02150(FR-A740-00230 to 01100)
1%: FR-A720-02880(FR-A740-01440) or more
*2
Differ according to capacities. (FR-A720-02150(FR-A740-01100) or less/FR-A720-02880(FR-A740-01440) or more)
*3
Differ according to capacities. (FR-A720-00330(FR-A740-00170) or less/FR-A720-00460(FR-A740-00230) or more)
*4
Differ according to capacities. (FR-A720-00330(FR-A740-00170) or less/FR-A720-00460 to 02150(FR-A740-00230 to 01100)/FR-A720-02880(FR-A740-
01440) or more)
*5
Differs according to the voltage class. (200V class/400V class)
*6
Setting can be made only when the FR-A7AP is mounted.
84
Name
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400Hz
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
0 to 400%
0 to 300%
10, 100
0, 1
0 to 63
0, 1
0, 1
0, 1
0, 1, 2, 3
Minimum
Setting Range
Setting
Increments
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.01Hz
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
1
1
1
1
1
1
1
Refer
Customer
Initial Value
to
Setting
Page
258
258
0Hz
289
0%
289
60
Hz
289
100%
289
0Hz
289
20%
289
Hz
289
60
100%
289
0Hz
289
0%
289
Hz
289
60
100%
289
0%
295
0%
295
150%
295
100%
295
0%
295
20%
295
150%
295
100%
295
10/100
392
*2
1
389
58
389
0
390
0
391
0
394
0
392

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Table of Contents