Download  Print this page

Mitsubishi Electric FR-A700 Instruction Manual Page 263

Fr-a700 series to 03460-na/09620-na/00330-n4/00170-n4.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482

Advertisement

(2) Display set frequency during stop (Pr. 52)
⋅ When Pr. 52 is set to "100", the set frequency monitor
is displayed during a stop and the output frequency
monitor is displayed during operation. (LED of Hz
flickers during stop and is lit during running.)
⋅ When Pr. 52 = "100", the set frequency displayed at a
stop indicates frequency to be output when the start
command is on.
Different from the frequency setting displayed when
Pr. 52 = "5", the value based on maximum/minimum
frequency and frequency jump is displayed.
REMARKS
⋅ During an error, the output frequency at error occurrence appears.
⋅ During MRS, the values displayed are the same as during a stop.
⋅ During offline auto tuning, the tuning status monitor has priority.
(3) Operation panel (FR-DU07) I/O terminal monitor (Pr. 52)
⋅ When Pr. 52 is set to any of "55 to 57", the I/O terminal states can be monitored on the operation panel (FR-DU07).
⋅ The I/O terminal monitor is displayed on the third monitor.
⋅ The LED is on when the terminal is on, and the LED is off when the terminal is off. The center line of LED is always on.
Pr. 52 Setting
55
Display the I/O and output terminal ON/OFF status of the inverter unit.
56 *
Display the input terminal ON/OFF status of the digital input option (FR-A7AX).
57 *
Display the output terminal ON/OFF status of the digital output option (FR-A7AY) or relay output option (FR-A7AR).
* You can set "56" or "57" even if the option is not fitted. When the option is not fitted, the monitor displays are all off.
⋅ On the unit I/O terminal monitor (Pr. 52 = "55"), the upper LEDs denote the input terminal status and the lower the
output terminal status.
RM
AU
RH
RL
RT
RUN
ABC1
SU
ABC2
IPF
⋅ On the input option terminal monitor (Pr. 52 = "56"), the decimal point LED of the first digit LED is on.
X1
X4
X2
X3
X0
X12
X10
X13
X11
X14
⋅ On the input option terminal monitor (Pr. 52 = "57"), the decimal point LED of the second digit LED is on.
Y1
Y4
Y2
Y0
Y3
RA3
RA1
RA2
RES
JOG
STOP
STF
CS
MRS
STR
OL
Free
Free
FU
Free Free
Free
X7
X5
X8
X6
X9
X15
Free
DY
Free
Free
Free
Y5
Y6
Decimal point LED of second digit LED is always on
Monitor display and monitor output signal
Type of Monitor
During
running/stop
Output
Output
frequency
frequency
Output current
Output voltage
Alarm display
Monitor Description
Input terminal
Center line is always on
Output terminal
Center line is always on
Free
Decimal point LED of first digit LED is always on
FR-A7AY
Center line is always on
FR-A7AR
Pr. 52
0
100
During
During
stop
running
Set
Output
frequency
frequency
Output current
Output voltage
Alarm display
- Display example -
When signals STF,
RH and RUN are on
Hz
MON P.RUN
A
PU
EXT
V
REV
FWD
NET
4
253

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-A700

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Comments to this Manuals

Symbols: 0
Latest comments: