(3) Set frequency when stop-on-contact control (Pr. 270 = 1, 3) is selected
⋅ The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are selected together.
Bold frame indicates stop-on-contact control is valid.
⋅ Stop-on-contact control is disabled when remote setting function is selected (Pr. 59 = 1 to 3).
Input Signal (
= on)
RH
RM
RL
RT
JOG
CAUTION
⋅ Changing the terminal function using any of Pr. 178 to Pr. 189 may affect the other functions. Please make setting after confirming
the function of each terminal.
♦ Parameters referred to ♦
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27 (multi-speed setting)
Pr. 15 Jog frequency
Refer to page 168
Pr. 22 Stall prevention operation level, Pr. 48 Second stall prevention operation current
Pr. 22 Torque limit level
Refer to page 99
Pr. 59 Remote function selection
Pr. 72 PWM frequency selection
Pr. 79 Operation mode selection
Pr. 95 Online auto tuning selection
Pr. 128 PID action selection
Pr. 178 to Pr. 189 (input terminal function selection)
Pr. 270 = 2, 3 (load torque high speed frequency control)
Set Frequency
Pr. 4 Multi-speed setting (high speed)
Pr. 5 Multi-speed setting (middle speed)
Pr. 6 Multi-speed setting (low speed)
By 0 to 5V(0 to 10V), 4 to 20mA
input
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 25 Multi-speed setting (speed 5)
Pr. 4 Multi-speed setting (high speed)
Pr. 15 Jog frequency
Pr. 24 Multi-speed setting (speed 4)
Pr. 5 Multi-speed setting (middle speed)
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Refer to page 166
Refer to page 170
Refer to page 279
Refer to page 308
Refer to page 197
Refer to page 355
Refer to page 228
Refer to page 368
Motor brake and stop operation
Input Signal (
= on)
RH
RM
RL
RT
JOG
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
Pr. 26 Multi-speed setting (speed 6)
Pr. 27 Multi-speed setting (speed 7)
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 15 Jog frequency
Pr. 6 Multi-speed setting (low speed)
Pr. 15 Jog frequency
By 0 to 5V(0 to 10V), 4 to 20mA
input
Refer to page 150
Set Frequency