Mitsubishi Electric FR-A700 Instruction Manual page 57

Fr-a700 series to 03460-na/09620-na/00330-n4/00170-n4
Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

(2) FR-BR-(H) connection example with resistor unit
Three phase AC
power supply
*1
Connect the inverter terminals (P/+, N/-) and brake unit (FR-BU2) terminals so that their terminal names match with each other.
(Incorrect connection will damage the inverter and brake unit.)
*2
When the power supply is 400V class, install a step-down transformer.
*3
Be sure to remove a jumper across terminal PR-PX when using the FR-BU with the inverter of FR-A720-00330 (FR-A740-
00170) or less.
*4
The wiring distance between the inverter, brake unit (FR-BU) and resistor unit (FR-BR) should be within 5m (16.4feet). Even
when the wiring is twisted, the cable length must not exceed 10m (32.8feet).
*5
Normal: across TH1-TH2...close, Alarm: across TH1-TH2...open
CAUTION
⋅ Do not remove a jumper across terminal P/+ and P1 except when connecting a DC reactor.
(3) Connection example with MT-BR5 type resistor unit
Three phase AC
power supply
*1
Connect the inverter terminals (P/+, N/-) and brake unit (FR-BU2) terminals so that their terminal names match with each other.
(Incorrect connection will damage the inverter and brake unit.)
*2
When the power supply is 400V class, install a step-down transformer.
*3
The wiring distance between the inverter, brake unit (FR-BU2) and resistor unit (MT-BR5) should be within 5m (16.4feet). If
twisted wires are used, the distance should be within 10m (32.8feet).
*4
Normal: across TH1-TH2...open, Alarm: across TH1-TH2...close
*5
CN8 connector used with the MT-BU5 type brake unit is not used.
CAUTION
⋅ When replacing the existing MT-BU5 type brake unit, set "2" in Pr. 0 Brake mode selection of the FR-BU2, "1" in Pr. 30 Regenerative
function selection and "10%" in Pr. 70 Special regenerative brake duty (refer to page 204) of the inverter.
MCCB
MC
R/L1
S/L2
T/L3
Inverter
PR
*3
PX
T
*2
MCCB
MC
R/L1
U
V
S/L2
T/L3
W
P/+
N/-
Inverter
*5
Connection of stand-alone option units
ON
T
*2
MC
MC
FR-BR
Motor
U
P
TH1
V
IM
PR
W
TH2
*4
FR-BU2
PR
P/+
P/+
*1
N/-
N/-
BUE
SD
*4
5m or less
ON
OFF
CR1
Motor
IM
MC
MC
*3
5m
or less
*1
P
N
P
P
*3
PR
BUE
PR
SD
Brake unit
Resistor unit
FR-BU2
MT-BR5
OFF
*5
A
B
C
*4
TH1
CR1
TH2
47
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Table of Contents