(5) Main differences and compatibilities with the FR-A500(L) series
Item
V/F control
Control method
Advanced magnetic flux vector control
User group 1 (16), user group 2 (16)
(Pr. 160, Pr. 173 to Pr. 175)
User initial value setting (Pr. 199)
Changed/cleared
functions
Long wiring mode
(Pr. 240 setting 10, 11)
Intelligent mode selection
(Pr. 60)
Program operation
(Pr. 200 to Pr. 231)
PID action set point setting
(Pr. 133)
Number of motor poles
(Pr. 81 , Pr. 144)
Performing parameter clear and all clear (H5A96,
HAA99) with the FR-A7ND clears Pr. 345 and Pr. 346.
Terminal block
Removable terminal block
PU
FR-PU04, DU04
Plug-in options
Computer link, relay output option
FR-A5NR
· FR-A740-00023 to 00250, 00470 to 01800, 03250, 04320 are compatible in mounting dimensions
For the FR-A740-00310, 00380, an optional intercompatibility attachment (FR-AAT) is necessary.
Installation size
· Heatsink protrusion attachment is not compatible.
Also, the panel cut dimension of 00023 to 00126, 00310, 00380, 02160 or more is not compatible.
Appendix 1-2 Replacement of the FR-A200 <EXCELENT> series

Instructions for installation

• When using the installation holes of the FR-A200(E) series, FR-A5AT (intercompatibility attachment) is necessary.
FR-A500(L)
Dedicated plug-in option (incompatible)
FR-A700
V/F control
Advanced magnetic flux vector control
Real sensorless vector control
Vector control (used with a plug-in option FR-A7AP)
User group (16) only
Setting methods were partially changed
(Pr. 160, Pr. 172 to Pr. 173)
User initial value setting (Pr. 199) was cleared
Substitutable with the copy function of the operation
panel (FR-DU07)
Setting is not necessary
(Pr. 240 settings "10" and "11" were cleared)
Parameter number change
(Pr. 60 Energy saving control selection)
(Pr. 292 Automatic acceleration/deceleration)
Function was cleared
Addition of "9999" to PID action set point (Pr. 133)
setting (a value input from terminal 2 is a set point)
Setting the number of motor poles in Number of motor
poles (Pr. 81) automatically changes the speed setting
switchover (Pr. 144) setting.
Pr. 345 and Pr. 346 are not cleared.
Removable terminal block
Upward compatibility (A500 terminal block mountable)
FR-PU07
FR-DU07
FR-PU04 (Some functions, such as parameter copy,
are unavailable.)
FR-DU04 unavailable
Built into the inverter
(RS-485 terminals, relay output 2 points)
443