Download  Print this page

Mitsubishi Electric FR-A700 Instruction Manual Page 415

Fr-a700 series to 03460-na/09620-na/00330-n4/00170-n4.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482

Advertisement

Operation Panel
Indication
Name
Regenerative overvoltage shut-off during acceleration
If regenerative energy causes the inverter's internal main circuit DC voltage to reach or exceed the
Description
specified value, the protective circuit is activated to stop the inverter output. The circuit may also be
activated by a surge voltage produced in the power supply system.
Check point
Check for too slow acceleration. (e.g. during descending acceleration in vertical lift load)
· Decrease the acceleration time.
Corrective action
· Use regeneration avoidance function (Pr. 882 to Pr. 886). (Refer to page 377.)
Operation Panel
Indication
Name
Regenerative overvoltage shut-off during constant speed
If regenerative energy causes the inverter's internal main circuit DC voltage to reach or exceed the
Description
specified value, the protective circuit is activated to stop the inverter output. The circuit may also be
activated by a surge voltage produced in the power supply system.
Check point
Check for sudden load change.
· Keep load stable.
Corrective action
· Use regeneration avoidance function (Pr. 882 to Pr. 886). (Refer to page 377.)
· Use the brake unit or power regeneration common converter (FR-CV) as required.
Operation Panel
Indication
Name
Regenerative overvoltage shut-off during deceleration or stop
If regenerative energy causes the inverter's internal main circuit DC voltage to reach or exceed the
Description
specified value, the protective circuit is activated to stop the inverter output. The circuit may also be
activated by a surge voltage produced in the power supply system.
Check point
Check for sudden speed reduction.
· Increase the deceleration time. (Set the deceleration time which matches the inertia of moment of
Corrective action
· Decrease the braking duty.
· Use regeneration avoidance function (Pr. 882 to Pr. 886). (Refer to page 377.)
· Use the brake unit or power regeneration common converter (FR-CV) as required.
Operation Panel
Indication
Name
Inverter overload shut-off (electronic thermal relay function)
If a current not less than 150% of the rated output current flows and overcurrent shut-off does not occur
Description
(220% or less), inverse-time characteristics cause the electronic thermal relay to be activated to stop
the inverter output in order to protect the output transistors. (overload immunity 150%
Check point
Check the motor for use under overload.
Corrective action
Reduce the load weight.
*1
When ND is selected. (Refer to page 432.)
Operation Panel
Indication
Name
Motor overload shut-off (electronic thermal relay function)
The electronic thermal relay function in the inverter detects motor overheat due to overload or reduced
cooling capability during constant-speed operation and pre-alarm (TH display) is output when the
temperature reaches 85% of the Pr. 9 Electronic thermal O/L relay setting and the protection circuit is
Description
activated to stop the inverter output when the temperature reaches the specified value. When running
a special motor such as a multi-pole motor or multiple motors, provide a thermal relay on the inverter
output side since such motor(s) cannot be protected by the electronic thermal relay function.
1. Check the motor for use under overload.
Check point
2. Check that the setting of Pr. 71 Applied motor for motor selection is correct. (Refer to page 185.)
3. Check that stall prevention operation setting is correct.
1. Reduce the load weight.
Corrective action
2. For a constant-torque motor, set the constant-torque motor in Pr. 71 Applied motor.
3. Check that stall prevention operation setting is correct. (Refer to page 150.)
*2
Resetting the inverter initializes the internal thermal integrated data of the electronic thermal relay function.
E.OV1
E.OV2
E.OV3
the load)
E.THT
E.THM
Causes and corrective actions
FR-PU04
OV During Acc
FR-PU07
FR-PU04
Stedy Spd OV
FR-PU07
FR-PU04
OV During Dec
FR-PU07
FR-PU04
Inv. Overload
FR-PU07
*2
FR-PU04
Motor Overload
FR-PU07
*2
60s)
*1
5
405

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-A700

This manual is also suitable for:

Fr-a720-00030Fr-a740-00015

Comments to this Manuals

Symbols: 0
Latest comments: