Function (Parameter) List - Mitsubishi Electric FR-S500E Instruction Manual

Frequency inverter
Table of Contents

Advertisement

Function (Parameter) list

2.1 Function (Parameter) list

CAUTION
indicates that the setting can be changed during operation if Pr. 77 "parameter
write disable selection" has been set to "0" (factory setting). (Note that the Pr. 53, Pr.
70 and Pr. 72 values can be changed only during PU operation.)
Indica-
Parameter
tion
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
Multi-speed setting
4
(high speed)
Multi-speed setting
5
(middle speed)
Multi-speed setting
6
(low speed)
7
Acceleration time
8
Deceleration time
Electronic thermal O/L
9
relay
Extended function
30
display selection
Operation mode
79
selection
*1. The factory setting varies with the inverter capacity: 5% for FR-S540E-1.5K and 2.2K, 4%
for FR-S540E-3.7K.
Setting
Name
Range
0 to 15%
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 120Hz
0 to 999s
0 to 999s
0 to 50A
0, 1
0 to 4, 7, 8
46
Minimum
Factory
Setting
Setting
Increments
6%/5%/
0.1%
4%/
(*1)
0.1Hz
50Hz
0.1Hz
0Hz
0.1Hz
50Hz
0.1Hz
50Hz
0.1Hz
30Hz
0.1Hz
10Hz
0.1s
5s
0.1s
5s
Rated
0.1A
output
current
1
0
1
0
Cus-
Refer
tomer
To:
Setting
61
62
62
63
64
64
64
65
65
67
78
107

Advertisement

Table of Contents
loading

Table of Contents