Sp9-Xxx: Others - Ricoh D025 Service Manual

Table of Contents

Advertisement

System Service Mode

SP9-XXX: Others

9511
Skew Origin Set
001 M: Skew Motor
002 C: Skew Motor
003 Y: Skew Motor
9911
[Pressure Roller Condition]
Normal: Threshold:
Upper Limit
001
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the input voltage of the IH inverter is
more than 93% (adjustable with SP1-916-026).
Normal: Threshold:
Lower Limit
002
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the input voltage of the IH inverter is more
than 93% (adjustable with SP1-916-026).
Coefficient: Low
003
DFU
Adjusts the coefficient value of the temperature correction for ferrite roller
rotation when the the fusing unit is in the low temperature.
D023/D025
*CTL
These SPs reset the skew correction value
(SP2-119-001 to -003) to "0".
*ENG
[0 to 200 / 140 / 1 deg/step]
*ENG
[0 to 200 / 120 / 1 deg/step]
[0 to 3 / 2 / 1 /step]
0: No effect
*ENG
1: Normal
2: High
3: Highest
8-410
SM Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

D023

Table of Contents