5.1.3 SERVICE TABLES

SP1-xxx: Feed

1001*
Leading Edge Registration
Adjusts the printing leading edge registration using the trimming area pattern
(SP2-902-3, No.11).
Use  to toggle between ± before entering the value. Specification: 3 ±2 mm
1002*
Side-to-Side Registration
Adjusts the printing side-to-side registration from the 3rd paper feed station using
the trimming area pattern (SP2-902-3, No.11).Tray3, Tray4 for Paper Feed Unit.
Use the  key to toggle between + and – before entering the value. Specification:
2 ±1.5 mm
1002 1
Tray 1
1002 2
Tray 2
1002 3
Tray 3
1002 4
Tray 4
1002 5
From Duplex Tray
1002 6
Bypass Feed
1002 7
LCT (if present)
1003*
Registration Buckle Adjustment
Adjusts the relay clutch timing at registration. Relay clutch timing determines the
amount of paper buckle at registration. (A "+" setting causes more buckling.)
1003 1
Trays 2,3,4 LCT
1003 2
Duplex
1003 5
Bypass
1003 4
Tray 1 Feed
1003 5
Bypass Thick Paper
1007*
By-pass Feed Paper Size Display
Displays the paper width sensor data for the by-pass feed table.
1012*
Exit Junction Solenoid Start Timing
Adjusts the timing of the solenoids at the entrance and exit of the paper exit
section to accommodate the increased speed of the duplex unit.
This SP has been added to compensate for the increased operation speed of the
duplex unit for this machine. Increase the value if the leading edges are jamming.
Decrease the value if trailing edges are bending at the entrance
1012 1*
Exit Entrance Junction
Solenoid
1012 2*
Exit Last Junction Solenoid
SM
SERVICE PROGRAM MODE
[+9 ~ –9 / 3.0 / 0.1 mm]
[–9 ~ +9/ +3.0 mm / 0.1 mm step]
[–9 ~ +9/ +3.0 mm / 0.1 mm step]
[–9~ +9/ +2.0 mm / 0.1 mm/step]
[–9~ +9/ +2.0 mm / 0.1 mm/step]
[–9 ~ +9/ +0.0 mm / 0.1 mm/step]
[–9 ~ +9/ +3.0 mm / 0.1 mm/step]
[–9 ~ +9/ +1.5 mm / 0.1 mm/step]
[–9 ~+9 / 0 /1 mm step]
B135: [200 ~ 450 ms / 370 ms / 10 ms]
B138: [200 ~ 450 ms / 300 ms /10 ms]
B135: [200 ~ 450 ms / 370 ms / 10 ms]
B138: [200 ~ 450 ms / 370 ms /10 ms]]
5-5