004 Coefficient: Mid.
005 Coefficient: High
Stand-by: Threshold:
Upper Limit
006
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the input voltage of the IH inverter is
93% or less (adjustable with SP1-916-026).
Stand-by: Threshold:
Lower Limit
007
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the input voltage of the IH inverter is 93%
or less (adjustable with SP1-916-026).
Mid. Thick: A3:
Threshold: Upper Limit
008
Specifies the threshold temperature of the pressure roller between M (middle)
and H (high). This SP is referred when the paper of 275 mm width or more is
used in the middle thick paper and 205/154 mm/sec line speed mode.
Mid. Thick: A3:
Threshold: Lower Limit
009
Specifies the threshold temperature of the pressure roller between L (low) and
M (middle). This SP is referred when the paper of 275 mm width or more is
used in the middle thick paper and 205/154 mm/sec line speed mode.
SM Appendix
*ENG
[0 to 3 / 1 / 1 /step] DFU
*ENG
[0 to 3 / 0 / 1 /step] DFU
*ENG
[0 to 200 / 180 / 1 deg/step]
*ENG
[0 to 200 / 120 / 1 deg/step]
*ENG
[0 to 200 / 200 / 1 deg/step]
*ENG
[0 to 200 / 190 / 1 deg/step]