Dedicated Transmission Parameters
adjust this byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1
second.
Range:
0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No
Tx level
Bit4
Bit3
0
0
0
0
0
0
0-4
0
0
0
0
0
1
1
1
Cable equalizer
Bit 7: 0, Bit 6: 0, Bit 5: 0 = None
Bit 7: 0, Bit 6: 0, Bit 5: 1 = Low
5-7
Bit 7: 0, Bit 6: 1, Bit 5: 0 = Medium
Bit 7: 0, Bit 6: 1, Bit 5: 1 = High
Bit 7: 1, Bit 6: 1, Bit 5: 1 = Disabled
D393
FUNCTION
Bit2
Bit1
Bit0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
1
1
1
1
1
Disabled
If communication with a particular
remote terminal often contains
0
errors, the signal level may be
–1
inappropriate. Adjust the Tx level for
communications with that terminal
–2
until the results are better.
–3
If the setting is "Disabled", the NCU
parameter 01 setting is used.
–4
Do not use settings other
than listed on the left.
–15
Use a higher setting if there is signal
loss at higher frequencies because
of the length of wire between the
modem and the telephone exchange
when calling the number stored in
this Quick/Speed Dial.
Also, try using the cable equalizer if
one or more of the following
symptoms occurs.
Communication error with error
148