Bit Switches

4.3 BIT SWITCHES
Do not adjust a bit switch or use a setting that is described as "Not used", as this
may cause the machine to malfunction or to operate in a manner that is not
accepted by local regulations. Such bits are for use only in other areas, such as
Japan.
Default settings for bit switches are not listed in this manual. Refer to the System
Parameter List printed by the machine.

4.3.1 SYSTEM SWITCHES

System Switch 00 [SP No. 1-101-001]
No
FUNCTION
Dedicated transmission
0
parameter programming
0: Disabled, 1: Enabled
1
Not used
Technical data printout on the
Journal
2
0: Disabled
1: Enabled
e.g. 0000 (1) // 32 (2) V34 (3) // 288 (4) // 264 (5) // L0100 (6) 03 (7) 04 (8)
(1): EQM value (Line quality data). A larger number means more errors.
(2): Symbol rate (V.34 only)
(3): Final modem type used
(4): Starting data rate (for example, 288 means 28.8 kbps)
(5): Final data rate
D393
(6): Rx revel (refer to the note after this table for how to read the rx level)
(7): Total number of error lines that occurred during non-ECM reception.
COMMENTS
Set this bit to 1 before changing any dedicated
transmission parameters.
Reset this bit to 0 after programming dedicated
transmission parameters.
Do not change
1: Instead of the personal name, the following data
are listed on the Journal for each G3
communication.
68
SM