Ricoh D025 Service Manual page 1370

Table of Contents

Advertisement

Code
Meaning
phase 2 – line probing.
The line was disconnected
due to a timeout in V.34
0-81
phase 3 – equalizer
training.
The line was disconnected
due to a timeout in the V.34
0-82
phase 4 – control channel
start-up.
The line was disconnected
due to a timeout in the V.34
0-83
control channel restart
sequence.
The line was disconnected
due to abnormal signaling
0-84
in V.34 phase 4 – control
channel start-up.
The line was disconnected
due to abnormal signaling
0-85
in V.34 control channel
restart.
The line was disconnected
because the other terminal
requested a data rate
0-86
using MPh that was not
available in the currently
selected symbol rate.
The control channel started
0-87
after an unsuccessful
primary channel.
SM
Suggested Cause/Action
low signal level can cause these errors.
If these errors happen at the transmitting terminal:
Try making a call at a later time.
Try using V.17 or a slower modem using
dedicated tx parameters.
Try increasing the tx level.
Try adjusting the tx cable equalizer setting.
If these errors happen at the receiving terminal:
Try adjusting the rx cable equalizer setting.
Try increasing the tx level.
Try using V.17 or a slower modem if the same
error is frequent when receiving from multiple
senders.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
The signal did not stop within 10 s.
Turn off the machine, then turn it back on.
If the same error is frequent, replace the FCU.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.