003 Specifies the threshold time for entering the temperature correction mode. If a
job continues for the time specified with this SP, the machine enteres the
temperature correction mode.
Offset Value: Plain: Low Temp.
Specified the offset temperature for the plain paper in the low temperature. The
004
machine decreases this temperature when a job continues for 600 seconds
(adjustable with SP9-965-003) and the environment temperature is 17°C or
less.
Offset Value: Plain: Normal/High
Temp.
005 Specified the offset temperature for the plain paper in the low temperature. The
machine decreases this temperature when a job continues for 600 seconds
(adjustable with SP9-965-003) and the environment temperature is more than
17°C and 30°C or less.
Offset Value: M-Thick: Low Temp.
Specified the offset temperature for the middle thick paper in the middle
006
temperature. The machine decreases this temperature when a job continues
for 600 seconds (adjustable with SP9-965-003) and the environment
temperature is 17°C or less.
Offset Value: M-Thick: Normal/High
Temp.
007 Specified the offset temperature for the middle thick paper in the middle
temperature. The machine decreases this temperature when a job continues
for 600 seconds (adjustable with SP9-965-003) and the environment
temperature is more than 17°C and 30°C or less.
SM Appendix
*ENG
[0 to 1200 / 600 / 10 sec/step]
*ENG
[0 to 20 / 5 / 1 deg/step]
*ENG
[0 to 20 / 5 / 1 deg/step]
*ENG
[0 to 20 / 5 / 1 deg/step]
*ENG
[0 to 20 / 5 / 1 deg/step]
8-413