3-10 ENCODER SCALE REPLACEMENT

1
Remove the following covers.
LEFT COVER
I/S COVER
TOP COVER
FRONT RAIL COVER
FRONT COVER
2
Turn on the SUB POWER SW while pressing the Left,
Right and Down keys to enter the SERVICE MODE.
3
Select [CAP&WIPER CTRL] > [CAP] > [OPEN], and
press the [ENTER] key. The CAPPING UNIT moves
down and allows you to move the HEAD CARRIAGE by
hand.
4
Move the HEAD CARRIAGE slowly leftwards.
Be careful that the head does not strike the
media or media clamp.
FRONT RAIL COVER
LEFT COVER
[
], [
MENU
SERVICE MENU
SERVICE MENU
CAP&WIPER CTRL
CAP&WIPER CTRL
CAP
CAP
OPEN
3-41
TOP COVER
I/S COVER
FRONT COVER
], [
] + POWER ON
[MENU] key
[
]
[
]
[ENTER]

Hide quick links: