Roland VersaCamm SP-540V Service Notes page 102

Wide format printer
Hide thumbs Also See for VersaCamm SP-540V:
Table of Contents

Advertisement

SERVICE MENU
PINCH ADJUST
Error compensation of the pinch roller position is performed. An error message is displayed when there is an
error more than 5 mm.
[Operation Procedure]
1. Slide the right Pinch Roller to the right end, and lower the pinch roll lever.
2. Select the [PINCH ADJUST] menu in the [SERVICE MENU] and press the [ENTER] key to perform.
3. A cutting carriage moves and the position of a right pinch roller is detected.
4. When it is complete, [SETUP COMPLEATED] is displayed.
* A compensation value is described in a service report.
SERVICE MENU
CAP ADJUST
To adjust the cap adjustment value and check the height of the cap, refer to the instruction of the [CAP HEIGHT ADJUSTMENT].
SERVICE MENU
CROPMARK SENS
This menu is for checking output level of cropmark sensor.
Refer to [Cropmark sensor adjustment].
This menu is for adjusting output level of cropmark sensor.
There are three levels, 0, +1, and +2, in a setting value.
When detection of CROP MARK does not work with an default value,
detection of CROP MARK may succeed by adjusting this value.
SERVICE MENU
FORCE ADJUST
This menu is for adjusting the Tool Pressure.
Refer to [TOOL PRESSURE ADJUSTMENT].
* When the pinch roll is not downed, display.
(Three beeps) It continues by pinch roll down.
LOWER PINCHIROLL
* When the pinch roll is downed, display.
NOW PROCESSING..
CAP ADJUST
ADJUST POD.
CAP ADJUST
CHECK GAP
CROPMARK SENS
OUTLEVEL CHECK
CROPMARK SENS
ADJUST
FORCE ADJUST
30gf
FORCE ADJUST
200gf
At the time of a normal end
(one beep)
PINCH ADJUST
SETUP COMPLETE
PINCH ADJUST
1.150 mm
A compensation value is displayed.
At the time of an error
(three beeps)
PINCH ADJUST
FAILED !!
ADJUST POD.
0.00
-2.00
CHECK GAP
0.00
MIN 0.7V MAX 2.3V
[ 2.0V ]
ADJUST
+2
+1
0 ~ +2
Default : 0
30gf
17
16
0~ 30
Default : 17
200gf
56
57
31~ 80
Default : 56
4-5
with [ ] and [ ] keys to
Use
change the
cap adjustment value.
The setting range is from -2.00 to +2.00. It
can be adjusted in 0.25 mm unit. The default
value is 0.00.
The cap can only be moved in the upward
direction in 0.25 mm unit. When you move in
the downward direction, press
[ ] key
to
move the cap to the lower end once and then
move in the upward direction in 0.25 mm unit.
4