Roland VersaCamm SP-540V Service Notes page 105

Wide format printer
Hide thumbs Also See for VersaCamm SP-540V:
Table of Contents

Advertisement

SERVICE MENU
PRINT&CUT ADJ.
4
SERVICE MENU
TEST PATTERN
SERVICE MENU
CLOCK CHECK
SERVICE MENU
DIP SW CHECK
SERVICE MENU
PUMP CHECK
PRINT&CUT ADJ.
TEST PRINT
PRINT&CUT ADJ.
FEED SETTING
PRINT&CUT ADJ.
SCAN SETTING
PRINT&CUT ADJ.
AUTO
PRINT&CUT ADJ.
TEST PRINT 2
PRINT&CUT ADJ.
SETTING2
Press [MENU] key
This menu is used for Print/Cut position Adjustment.
Refer to [Print/Cut Position Adjustment].
TEST PATTERN
HORIZONTAL
It is for checking the Head Alignment in Horizontal.
TEST PATTERN
BI-DIR.
It is for checking the Head Alignment in Bidirection.
TEST PATTERN
FILL
100% fill pattern of all heads will be printed.
Printing is done by 720 x 720dpi / 16 pass.
TEST PATTERN
BI-DIR.CHECK
It is for checking the shifting with Bidirection printing.
It will be printed in a whole width of the media.
CLOCK CHECK
0y000d00h00m00s
CLOCK CHECK B
0y000d00h00m00s
This menu is used for checking the REAL TIME CLOCK. Time being passed after the clock has started
to work will be displayed. (Year / Day / Hour / Minute / Second) When battery is run out, [B] will be displayed
at the upper right corner of the LCD. In this case, battery has to be replaced. However, the flag won't be
cleared even if battery is replaced.
Make sure to clear the flag by entering the Battery Flag Clear Menu and then pressing the [ENTER] key.
DIP SW CHECK
0000 0000
bit # [ 1 2 3 4
5 6 7 8]
This menu is used for checking the DIP SW on the MAIN BOARD. Status of bit#1 ~ #8 of the DIP SW
will be displayed as 0 for OFF and 1 for ON.
PUMP CHECK
PUMP SUCTION
PUMP CHECK
PUMP RELEASE
This menu is used for checking the Pump Motor. Rotation for Ink Suction Direction and Ink Drain
Direction can be checked. Rotation check will stop after 5 seconds.
FEED SETTING
-0.15mm
-0.23mm
SCAN SETTING
-0.40mm
-0.40mm
PRINT&CUT ADJ.
COMPLETED
To change the parameter, press [ENTER].
F: 0.40
----
S:-0.50
----
(-5.00~+5.00) Change in 0.01mm unit. Press [ENTER] to excute.
CLOCK CHECK
CLEAR BAT FLAG
NOW PROCESSING..
NOW PROCESSING..
4-8