Firmware Update Error Codes - Mitel 5610 IP Dect Stand Configuration And Administration Manual

Communications director platform and 5000 communications platform
Table of Contents

Advertisement

Configuration and Administration Guide
Field
Firmware Update Settings
Firmware update server address
Firmware path
Scheduled firmware update
Polling method
Frequency for relative searching
for new software
Hour for absolute searching for
new software
Minute for absolute searching
for new software
5. Click Save Changes.
6. Click Reboot. The next time that the stand polls the tftp server it will detect the new firmware
update and download it to the handsets.
NOTE: The duration of a firmware update is about 15 minutes per handset. The handsets are updated
serially (one handset at a time) with the firmware. All handsets that are associated with an IP DECT
Stand will not be operable until they are all updated with the new firmware.

Firmware Update Error Codes

A number of errors can occur when initiating a firmware update or while a firmware update is in
progress. The following list describes all error codes:
Code 0: No problems
This error code indicates that everything is working as specified.
Code 1: Wrong parameter
Code1 is an internal error code that indicates that the firmware update application cannot access the
selected software version (The selected software is not present in the dir list).
Code 2: Network not available
Description
Enter the DNS name or IP address
of the tftp server that contains
firmware update files.
Enter the path to the directory on the
tftp server that contains the firmware
update files. The path may contain
multiple directories. The path must
start with a slash and must end with
a slash. Backslashes are not
allowed.
If enabled, the IP DECT Stand
automatically checks your tftp site
for new firmware updates based on
the polling schedule and
automatically downloads new files. If
this field is set to disabled, no
checking is done and firmware
update files are not downloaded.
Allows you to configure the polling
method. You can configure the
stand to poll (check) for a firmware
update on your tftp site at a specific
time each day (Absolute), or to poll
at a regular time interval (Relative).
If you select the Relative polling
method, this is the time interval in
seconds between each poll.
If you select the Absolute polling
method, enter the time of day in
hours and minutes when you want
the poll to occur. Enter the hour
using a 24-hour clock
48
Values
Notes
String (max 31
characters) or IP
address
String (max 31
If you place the
characters)
files at the root of
the tftp server,
you can leave
this field blank.
Enable or
Enable
Disable
Absolute or
Recommended
Relative
setting is
Absolute
Seconds
3600 (every
hour)
0-23 [Hour]
2
(2 am)
0-59 [Min]
00