8 - 4
RS507 Hands-Free Imager Product Reference Guide

Charger

Imager Technical Specifications
Table 8-2
Item
Physical Characteristics
Dimensions (H x W x L):
Performance Characteristics
Charging Duration:
User Interface
LED:
Age Test Key
User Environment
Operating Temperature:
Storage Temperature:
Humidity:
Electrostatic Discharge
(ESD):
Power
External Power Supply:
Peripherals and Accessories
RS507 Batteries:
Regulatory
Electrical Safety:
EMI/RFI:
RoHS:
10.2 x 11.4 x 26.6 cm (4.02 x 4.49 x 10.50 in.) without cord and external power
supply.
Less than 4 hours (for both standard and extended capacity batteries).
One Bi color LED per charging bay.
Activate age test cycle for docked batteries.
0° to 50° C/32° to 122° F (charging is performed until battery temperature is
45° C/113° F/
-40° to 85° C/-40° to 158° F
5% to 85% (non-condensing)
±15kV air discharge, ±8kV direct discharge.
AC Input: 90-264 V AC 50-60 Hz with IEC320 C8 AC inlet
DC Output: 12 V/4.17A
Charges and tests both standard and extended capacity RS507 batteries.
Certified to UL60950-1, CSA C22.2 No. 60950-1, EN60950-1, IEC 60950-1
FCC Part 15 Class B, ICES-003 Class B
Compliance with RoHS standards.