Emergency Call Alarm; Man-Down And No-Movement Alarm - ASCOM i62 Configuration Manual

Vowifi handset
Hide thumbs Also See for i62:
Table of Contents

Advertisement

Configuration Manual
Ascom i62 VoWiFi Handset
6
In the Text indication for alarm on multiple press field or Text indication for alarm on
long press, enter the text to be displayed in the VoWiFi Handset when the alarm has
been activated.
7
In the Mode for automatic call after alarm drop-down list, select one of the following:
• Monitor - The loudspeaker is muted and the microphone is on.
• Loudspeaker - The loudspeaker is turned on.
• Ordinary - The loudspeaker is turned off.
6.8.4

Emergency Call Alarm

If enabled, an alarm will be sent when the user calls the defined Emergency number (for
example 112).
1
Select Alarm > Emergency call.
2
In the Emergency call alarm drop-down list, select one of the following:
• On - An alarm will be sent when the user calls the emergency number.
• Off - No alarm will be sent when the user calls the emergency number.
3
In the Alarm type text field,enter the text to be displayed in the VoWiFi Handset
when the alarm has been activated.
4
Select Device > Call.
5
In the Emergency number field, enter the emergency number.
If Emergency call alarm is enabled (see step 2), an alarm will be sent when the user
calls this number.
6.8.5

Man-down and No-movement Alarm

Note: Applicable to Protector only. The handset version must be WH1-AAAA/2A or above
(see label under battery cover). This function requires a license.
The following parameters are available under the Numbers and Templates tabs in PDM and
Device Manager:
Parameter name
Man-down alarm
Man-down detection time
Man-down warning angle
No-movement alarm
No-movement detection time Delay before the alarm is activated.
Warning phase duration
NM-MD extra delay used
NM-MD extra delay time
ALS
9 December 2011/ Ver. D
Description
Enable or disable the alarm.
Delay before the alarm is activated.
The VoWiFi Handset tilt from the
vertical at which the alarm is activated.
Enable or disable the alarm.
Delay before the activated alarm is
sent.
Enable or disable the possibility of an
extra delay.
Extra delay before the alarm is sent.
Enable or disable the Acoustic Location
Signal (ALS) after the alarm has been
sent.
Note: The ALS will not be activated if an
automatic call is established after an
alarm has been sent.
TD 92675EN
Value {default}
Enabled/Disabled
{Disabled}
5–255 s {7}
45, 60 {45}
Enabled/Disabled
{Disabled}
5–255 s {30}
1–255 s {7}
Yes/No {No}
1–20 min {10}
Yes/No {No}
47

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the i62 and is the answer not in the manual?

Table of Contents

Save PDF