9. STANDARD ADJUSTMENTS

9-29. Installing (replacing) the auxiliary clamp on the left side

If necessary, the auxiliary clamp can be removed from the right side and can be installed on the left side instead. In this case,
the following optional parts are required.
(Top)
1. Stop the air and then bleed the air. (Refer to "3-16. Adjusting the air pressure".)
2. Remove the feed base unit (1) from the bed. (Refer to "5-3. Feed mechanism" in the service manual.)
3. Disconnect the air tubes (2) and (3) from the joints (4) and (5).
4. Remove retaining ring C (6).
109
To install the auxiliary clamp on the left side, first have the
following option parts ready.
Ref. No.
(34)
SA9132001
(9) (10)
SA5683001
*
Be sure to remove the stickers (A) before using the air
hoses (9) and (10).
1604B
RH-9820
Code
Qty.
1
Auxiliary clamp L
assembly
2
Air hose (outer dia. 4
mm, inner dia. 2.5 mm,
length 750 mm)
Part name
1168B