11. ERROR CODES
Feed mechanism-related errors
Items with a "*" in the "Page" column should only be checked by a qualified technician.
Code
X-feed motor home position cannot be
detected.
E200
Problem with X-feed motor or poor X
home position sensor connection.
E201
X-feed motor stopped due to a problem.
Y-feed motor home position cannot be
detected.
E210
Problem with Y-feed motor or poor Y
home position sensor connection.
E211
Y-feed motor stopped due to a problem.
θ-feed motor home position cannot be
detected.
E220
Problem with θ-feed motor or poor θ home
position sensor connection.
θ-feed motor stopped due to a problem.
E221
119
Cause
Remedy
Turn off the power, and then check that the X-feed motor
connector P10 is connected at the PMD P.C. board and
that the X pulse motor encoder connector P20 is
connected at the main P.C. board.
Turn off the power, and then check if there are any
problems in the X-feed direction.
Turn off the power, and then check that the Y-feed motor
connector P8 is connected at the PMD P.C. board and that
the Y pulse motor encoder connector P4 and sensor
connector P8 are connected at the main P.C. board.
Turn off the power, and then check if there are any
problems in the Y-feed direction.
Turn off the power, and then check that the θ-feed motor
connector P3 is connected at the PMD P.C. board and that
the θ-feed motor encoder connector P5 is connected at
the main P.C. board.
Turn off the power, and then check if there are any
problems in the θ-feed direction.