Adjusting The Work Clamp Positions - Brother RH-9820 Instruction Manual

Electronic eyelet button holer
Hide thumbs Also See for RH-9820:
Table of Contents

Advertisement

9-19. Adjusting the work clamp positions

The positions of the work clamps relative to the needle plate can be adjusted forward, back and sideways.
*
Adjust the left and right work clamps so that they are both positioned at an equal distance from the needle drop position.
(The following describes how to adjust the position of the right-side work clamp.)
<Forward/back adjustment>
1. Loosen the socket bolt (1), and then move the position of the clamp arm (2) forward or back to adjust.
2. Next, adjust so that the side of work clamp R (3) is parallel to the side of the needle plate (4).
3. Once adjustment is complete, tighten the socket bolt (1).
<Sideways adjustment>
1. Loosen the two set screws (5), and then adjust the sideways position of the clamp lever (6).
2. Once adjustment is complete, tighten the two set screws (5).
*
Adjust the position for the left-side work clamp in the same way.
(Seen from directly to the right)
RH-9820
9. STANDARD ADJUSTMENTS
0511B
92