Brother RH-9820 Instruction Manual page 130

Electronic eyelet button holer
Hide thumbs Also See for RH-9820:
Table of Contents

Advertisement

11. ERROR CODES
Software-related errors
Items with a "*" in the "Page" column should only be checked by a qualified technician.
Code
Program version error between main and
E569
motor detected.
E580
Error in EEPROM version detected.
E581
Error in memory switch version detected.
E582
Error in parameter data version detected.
Device-related errors
Items with a "*" in the "Page" column should only be checked by a qualified technician.
Code
Lower thread trimmer does not operate,
E630
or lower thread trimming sensor is faulty.
Hammer is lowered, or hammer position
E650
sensor is faulty.
Hammer is not lowered, or hammer
E651
position sensor is faulty.
P.C. board-related errors
Items with a "*" in the "Page" column should only be checked by a qualified technician.
Code
E700
Abnormal rise in power supply voltage.
Abnormal rise in sewing machine motor
E701
drive voltage.
E705
Abnormal drop in power supply voltage.
Abnormal current detected in sewing
E710
machine motor.
E719
Problem detected with PMD P.C. board.
E740
Cooling fan does not operate.
If an error code that is not listed above appears or if carrying out the specified remedy does not solve the problem, contact the
place of purchase.
121
Cause
Cause
Cause
Remedy
Press the RESET key to clear the error.
* This error is displayed when a power supply motor
P.C.board
for
a
different
Replace with the power supply motor P.C.B. for the
RH-9820 as soon as possible.
Turn off the power and carry out level 3 initialization.
Turn off the power and carry out level 2 initialization.
Turn off the power and carry out level 1 initialization.
Remedy
Turn off the power, and then check that the valve harness
connector and sensor connector are inserted at the main
P.C. board.
Turn off the power, and then check that the hammer valve
harness connector and hammer position sensor connector
are inserted at the main P.C. board.
Turn off the power, and then check that the hammer valve
harness connector and hammer position sensor connector
are inserted at the main P.C. board.
Remedy
Turn off the power and check the input voltage.
Turn off the power, and then check the voltage.
Turn off the power and check the input voltage.
Turn off the power, and then check if there are any
problems with the sewing machine.
Turn off the power, and then check the PMD P.C. board.
Turn off the power, and then check that the cooling fan
sensor connector is connected at the main P.C. board.
RH-9820
Page
model
is
installed.
20*
62
62
62
Page
19*
19*
19*
Page
23*
20*
23*
*
20*
19*

Hide quick links:

Advertisement

Table of Contents
loading