Pump Drive Coupler Installation - Terex PT-30 Service Manual

Compact track loader
Hide thumbs Also See for PT-30:
Table of Contents

Advertisement

5. Remove the seat. Refer to Chapter 6. Seat Re-
moval.
6. Remove the fuel tank. Refer to Chapter 6. Fuel
Tank Removal.
7. Remove the auxiliary gear pump. Refer to Chap-
ter 10. Auxiliary Gear Pump Removal.
8. Remove the tandem pump. Refer to Chapter 10.
Tandem Pump Removal.
Loosen
Locking
Screw
Pump
Drive
Coupler
Figure 10-19
9. Loosen the locking screw that secures the pump
drive coupler to the drive shaft extending from
the end of the tandem pump.
Tandem Pump
Drive Shaft
Figure 10-20
10. Slide the pump drive coupler off the tandem
pump drive shaft.
Tandem
Pump
Pump
Drive
Coupler
10. Transmission and Drive Disassembly and Assembly

Pump Drive Coupler Installation

Tandem Pump
Drive Shaft
Figure 10-21
1. Slide the pump drive coupler all the way onto the
tandem pump drive shaft.
Tighten
Locking
Screw
Pump
Drive
Coupler
Figure 10-22
2. Tighten the locking screw that secures the pump
drive coupler to the tandem pump drive shaft.
3. Install the tandem pump. Refer to Chapter 10.
Tandem Pump Installation.
4. Install the auxiliary gear pump. Refer to Chapter
10. Auxiliary Gear Pump Installation.
5. Install the fuel tank. Refer to Chapter 6. Fuel
Tank Installation.
6. Install the seat. Refer to Chapter 6. Seat Instal-
lation.
7. Add fuel and manufacturer-approved hydraulic
fluid.